beautypg.com

BVA Hydraulics HF1005B User Manual

Page 4

background image

Figure 2 - Illustration to bleed air from system

BEFORE USE

1. Before using this product, read the owner's manual

completely and familiarize yourself thoroughly with the

product, its components and recognize the hazards

associated with its use.

2. Verify that the product and the application are compatible.

If in doubt, call BVA Hydraulics Technical Service (888)

332-6419.

3. Inspect before each use. Do not use if bent, broken, leaking

or damaged components are noted.

4.

Replace worn or damaged parts and assemblies with BVA

Hydraulics authorized replacement parts only. Lubricate

as instructed in Maintenance Section.

5. Ensure method of confirming load is accurate and working

properly. Have gauge or load cell accuracy verified by

qualified personnel on a yearly basis.

OPERATION

Operate the hydraulic pump to advance and retract the

cylinder.

Do not continue pumping when cylinder is fully

extended. Internal pressure will build up and may damage

the seal of the cylinder.

To help prevent material fatigue if the cylinder is to

be used in a continuous application, the load should

not exceed 85% of the rated capacity.

Your cylinder, hose(s), couplings and pump all must

be rated for the same maximum operating pressure,

correctly connected and compatible with the hydraulic fluid

used. An improperly matched system can cause the system

to fail.

All personnel must be clear before lowering load.

MAINTENANCE

1. Inspect hoses and connections daily. Replace damaged

components immediately with BVA Hydraulics Replacement

Parts only.

2. Tighten connections as needed. Use pipe thread sealing

compound when servicing connections.

3. Always use clean, approved hydraulic fluid and change as

recommended or sooner if the fluid becomes contaminated

(never exceed 400 hours). Follow pump manufacturers

instructions for changing and adding hydraulic fluid. Use

only good quality hydraulic fluid. We recommend Mobil

DTE13M or equivalent when using with hand pump or air

pump; BVA Hydraulics Oil (F01) or equivalent when using

with electric pump.

Never use brake fluid, transmission

fluid, turbine oil, motor oil, alcohol, glycerin etc. Use of

other than good quality hydraulic oil will void warranty and

damage the cylinder, pump, hose etc.

4. Use an approved, high-grade pipe thread sealant to seal all

hydraulic connections. Teflon tape can be used if only one

layer of tape is used and it is applied carefully (two threads

back) to prevent the tape from being introduced into hydraulic

system. A piece of tape could travel through the system and

obstruct the flow of fluid and adversely affect function.

Lubrication & Cleaning

Keep cylinder clean at all times.

1. Any exposed threads (male or female) must be cleaned

and lubricated regularly, and protected from damage.

Lubricate with light machine oil.

2. If a cylinder or ram has been exposed to rain, snow,

sand, airborne abrasive, or any corrosive environment, it

must be cleaned, lubricated, and protected immediately

after exposure. Daily clean exposed ram with clean cloth

dampened with light machine oil. Protect exposed ram

from the elements at all times.

3. Keep the hydraulic system as free of dirt as possible. When

not in use, couplers must be sealed with dust covers. All

hose connections must be free of dirt and grime. Any

equipment attached to the cylinder must be kept clean.

Storage

Cylinders should be stored vertically with ram plunger fully

retracted in a dry, protected area, not exposed to corrosive

vapor, dust or other harmful elements. When a cylinder has

not been used for a period of 4 months, it should be connected

to a pump and fully extended and then retracted a minimum

of 5 times. This cycle will lubricate the cylinder wall, reducing

the possibility of corrosion and damage thereof.

How to remove faulty coupler:

If cylinder does not retract,:

1. Secure load by other means.

2. Depressurize pump and hose.

3. Remove the cylinder from application.

4. Disconnect and replace with new coupler.
Important: Do not attempt to grasp with pliers or wrench

without first wrapping the jaws of such tool with rags or

similar padding.

How to bleed air from system:

1. Place pump at a higher elevation than the hose and

cylinder as shown in figure 2 below.

2. Operate pump to fully extend and retract the cylinder 2 or

3 times. The objective is to force the air bubbles up hill

and back to the pump reservoir.

3. Follow pump instruction manual to bleed the air from

pump reservoir. On most pumps, air can escape by

opening the oil filler plug/screw.

4

!

!

!