Specifications, Rear panel – B&K Precision 9150-9153 - Datasheet User Manual
Page 2

2
w w w.bk prec ision.c om
Single Output Programmable DC Power Supplies
Models 9150, 9151, 9152 & 9153
a
Output Ratings
0 - 5.2 V
0 - 20 V
0 - 30 V
0 - 60 V
( 0 °C~40 °C)
0 - 60 A
0 - 27 A
0 - 18 A
0 - 9 A
Load Regulation
<0.01% + 0.5 mV
<0.01% + 1 mV
<0.01% + 1 mV
±(%of output+offset)
<0.1% + 10 mA
<0.1% + 5 mA
<0.1% + 2 mA
Line Regulation
<0.02% + 0.1 mV
<0.02% + 1 mV
<0.02% + 1 mV
±(%of output+offset)
<0.1% + 1 mA
<0.01% + 1 mA
<0.01% + 0.1 mA
Programming resolution
0.1 mV
1 mV
1 mV
1 mA
1 mA
0.1 mA
Readback/ Meter resolution
0.1 mV
0.1 mV
0.1 mV
1 mA
0.1 mA
0.1 mA
Front panel
0.1 mV
0.5 mV
0.5 mV
setting resolution
1 mA
1 mA
1 mA
Programming accuracy,
<0.02%+2 mV
<0.02%+6 mV
<0.02%+12 mV
12months (25 °C ± 5 °C) ±(%of output+offset)
<0.1%+30 mA
<0.1%+15 mA
<0.05%+10 mA
Readback/ Meter accuracy
<0.02%+1.5 mV
<0.02%+3 mV
<0.02%+6 mV
12months (25 °C ± 5 °C) ±(%of output+offset)
<0.05%+15 mA
<0.05%+10 mA
<0.05%+5 mA
Ripple & Noise
≤ 4 mVp-p
≤ 4 mVp-p
≤ 5 mVp-p
(20Hz ~20MHz)
15 mArms
5 mArms
3 mArms
Temperature coefficient,
<0.02%+2 mV
<0.02%+5 mV
<0.02%+10 mV
(0 °C~40 °C) ±(% of output+offset)
<0.1
%+30 mA
<0.1
%+15 mA
<0.05
%+5 mA
Readback temperature coefficient,
<0.02%+2 mV
<0.02%+5 mV
<0.02%+10 mV
±(% of output+offset)
<0.1
%+20 mA
≤ 0.05%+10 mA
≤ 0.05%+5 mA
Transient Response (for a change from 0 mA to
100 µs for output to
120 µs for output to
100 µs for output to
50 µs for output to
50% of maximum rated current)
recover to within 75 mV
recover to within 75 mV recover to within 50 mV recover to within 50 mV
DVM Accuracy
0~12V range: 0.02%+2mV
0~40V range: 0.02%+3mV
DVM Resolution
0~12V range: 0.1mV
0~40V range: 1mV
Milliohm Meter Accuracy
0.1% (for Voltage and Current ≥ 10% of full scale)
0.3% (for Voltage and Current ≥ 3% of full scale)
Weight
63.9 lbs, (29 kg)
Dimensions
16.88 in (W) x 3.47 in (H) x 18.06 in (D)
User accessible fuse
Temperature controlled
cooling fan
Serial interface connector for RS232 or
USB communication.
Remote Sense and digital
port functionality
Remote Interface
The power supplies can be remotely controlled
from any PC with USB or RS232 interface,
allowing the user to program and monitor all
parameters through easy to use SCPI commands.
The power supplies come with a RS232 to TTL
and a USB to TTL serial converter cable. The
average command processing time is 35 ms.
9150
9151
9152
9153
Included Accessories: User manual, power cord, RS232 and USB communication cable, application software installation disk, and certificate of calibration.
Optional: IT-E151 rack mount kit.
Specifications
models
Three Year Warranty
Rear panel
▲
Extra Features
The 9150 series’ digital port offers a variety of
configurations. The port provides Digital Input,
external Trigger and Remote Inhibit (RI)
functionality.
The RI mode can be used for turning several
power supplies On/Off simultaneously. External
triggering can be used in combination with List
mode.
v032212