beautypg.com

Electrical connection, Removal from the wall cupboard – Neff D4672X0 User Manual

Page 28

background image

28

Electrical connection

WARNING: THIS APPLIANCE MUST BE
EARTHED

IMPORTANT: Fitting a Different Plug:

The wires in the power cord are colour-
coded as follows:

Green and Yellow

– Earth

Blue

– Neutral

Brown

– Live

If you fit your own plug, the colours of
these wires may not correspond with the
identifying marks on the plug terminals.

Proceed as follows:

1. Connect the green and yellow (Earth)

wire to the terminal in the plug marked
‘E’ or with the symbol ( ), or
coloured green or green and yellow.

2. Connect the blue (Neutral) wire to the

terminal in the plug marked ‘N’ or
coloured black.

3. Connect the brown (Live) wire to the

terminal marked ‘L’, or coloured red.

The extractor hood may be connected to
a correctly installed earthed socket only.
Attach the earthed socket near the
extractor hood in an accessible position.
❑ The earthed socket should be

connected via its own power circuit.

If appliances do not feature the OFF

delay function, the indicator may start flas-
hing when the extractor hood has been
switched off for several hours via a separa-
te switch, even though the grease filters are
not yet saturated.
(See instructions for use, section on filter
and maintenance).

Electrical specifications:

These can be found on the rating plate
inside the appliance following removal of
the filter frames.

Before carrying out repairs, always

isolate the appliance.

Length of the connection cable: 1.30 m.

If permanent connection is required:

The extractor hood may only be connected
by an electrician registered with the local
electricity board.

A disconnecting device must be provided
on the installation side. Switches with a
contact opening of more than 3 mm and
all-pole disconnection are regarded as
disconnecting devices. These include LS
switches and contactors.

This extractor hood complies with EU
regulations on interference suppression.

1. Disconnect from power.

2. Disconnect pipes.

3. Remove filters.

4. Undo right and left fixing screws until the

extractor hood cannot drop any further.

Do not lift the extractor hood when

undoing the fixing screws.

5. Raise the extractor hood briefly until the

fixing lugs detach and the appliance can
be lowered.

Fastening screws may project.

When raising the extractor hood, do not
force in the filter drawer.

6. Preparing for re-installation:

Screw in the left and right fixing screws
until the lugs are pressed out at the
sides.

Removal from the wall
cupboard

This manual is related to the following products: