Use on couplings – GEARENCH SCT2036 PETOL SURGRIP Casing Tong User Manual
Page 12

10
With heavy duty belts (0.250 inch thick, 31 cords wide)
Diameter
Belt
Part
Number
Torque
Arm
Length
(inches)
Maximum
Torque
(foot-pounds)
Maximum
Line Pull
(pounds)
18
SCTB2036-18H
45.65
105,400
27,700
18 3/8
SCTB2036-1838H
45.83
106,600
27,900
18 5/8
SCTB2036-1858H
45.95
107,600
28,100
20
SCTB2036-20H
46.62
111,900
28,800
22
SCTB2036-22H
47.60
118,200
29,800
24
SCTB2036-24H
48.56
123,800
30,600
26
SCTB2036-26H
49.54
129,600
31,400
28
SCTB2036-28H
50.51
135,100
32,100
30
SCTB2036-30H
51.48
140,300
32,700
32
SCTB2036-32H
52.46
145,600
33,300
32 1/4
SCTB2036-3214H
52.58
145,900
33,300
32 1/2
SCTB2036-3212H
52.70
146,700
33,400
36
SCTB2036-36H
54.40
155,000
34,200
38
SCTB2036-38H
55.38
159,700
34,600
WARNING: Under no circumstances should the maximum working load be
exceeded. Always use a load cell or other calibrated indicating device to monitor
the line pull on the tong to avoid an overload.
Use on couplings
The yoke plates attached to the handle have three holes. One hole is used to fix the belt to the
yoke plates. One hole is marked “PIPE”, when this hole is fixed to the handle, the tong will
latch on the pipe for the appropriate belt. The third hole is marked “COUPLING”, this hole
will allow the tong to be latched onto a coupling with a diameter of one inch over the pipe
diameter.