Warning, Reg. 7 operation, Caution – Elmo Rietschle G-BH1 Extra instruction manual User Manual
Page 5: Reg. 9 maintenance warning

reg. 7 Operation
© Gardner Denver Deutschland GmbH
5 / 12
610.44479.40.000
reg. 5.2 Electric power connection
Point 5.2 “Electric power connection” in the
standard operating manual is no longer
applicable in any way whatsoever.
Information concerning this point must be
removed from the motor’s accompanying
documentation.
External earthing:
The unit must be earthed with an earth
conduction resistance of < 10
6
Ohm at the
position marked with a
!
Operating with a frequency converter
WARNING
Danger of personal injury and material
damage.
Only use frequency converters in accordance
with accompanying inspection document.
When using units with frequency converters, the
maximum rotation speed on the power rating
plate must be adhered to.
reg. 5.3 Connecting the piping / hoses
reg. 5.3.1 Suction branch
WARNING
Danger from foreign objects and
dirt in the unit!
Intruding foreign matter and foreign objects can
cause friction sparks and spark formation
through chafing.
Dust deposits in the unit can cause spark
formation through chafing.
Moreover, the impeller blades can break and
broken pieces can fly out.
install suitable protective devices (such as
filters) in the suction line according to RL
94/9/EG.
reg. 7 Operation
Start-up and switch-down
See chapter 6 “Initial operation”, sub-chapter 6.2
“Start-up and switch-down”.
Also be sure to pay attention to the following
important notices for operations:
WARNING
Danger of burns from hot surface on the unit
and from hot mediums!
The external surface of the unit can reach
temperatures of up to about 125ºC [257 ºF]
Do not touch when in operation.
Leave to cool down after switching it off.
CAUTION
Danger of overheating due to hot surfaces of
the unit!
The external surface of the unit can reach high
temperatures of up to about 125°C [257°F].
Temperature sensitive parts such as wiring or
electronic components must not come into
contact with unit surfaces.
reg. 9 Maintenance
WARNING
The operator is not allowed to carry out any
kind of maintenance, servicing and repair
work which requires the machine to be
dismantled.
The technical service must be consulted for
such cases.
WARNING
Danger of personal injury and material
damage.
Test the unit for leaks each time it is
dismantled.