Installation
5.3 Connecting
pipes
a) When on vacuum operation connect the suction
pipe at (Fig. 2/A) and when on pressure opera-
tion connect the pressure pipe at (Fig. 2/B).
NOTICE
Long and/or small bore pipework should be
avoided as this tends to reduce the capacity of
the blower.
Radial blowers must only be operated under
a throttled condition to avoid motor overload.
The units should not be used when not con-
nected to a system.
b) Check to ensure the intake line and pressure
connection are connected correctly.
5.2.1 Connection positions
Fig. 4 Connection positions
The radial blowers F-RER and F-REL can be opera-
ted in 4 different connection positions.
Standard version is position 01.
F-RER
F-REL