Malfunctions: Causes and elimination
8
Malfunctions: Causes and elimination
Fault
Cause
Troubleshooting
Important
Machine is
switched off
by the motor
protection
switch
Mains voltage/ Frequency
does not correspond with the
motor data
Check by qualifi ed electrician
Section 5.5
Check all electrical connec-
tions
Motor protection switch is not
set correctly
Blower operates without con-
nection to a system
Connect system
Section 5.3
Insuffi cient
suction ca-
pacity
Filter bags are contaminated
or full
Clean or discharge fi lter bags
Section 7.2.1
Suction pipe is too long or too
narrow
Check the the suction pipe
Section 5.3
Machine or system leaking
Check the pipework and screw con-
nections for leaks and to ensure that
they are fi rmly seated
Section 7.2
Machine gets
too hot
Ambient or intake temperature
is too high
Ensure it is being used properly
Section 2.3
Blower sucks too little air
Check the rotation direction resp. cross
sections of the pipes
Section 6.1.1
Section 5.3
Filter bags are contaminated
or full
Clean or discharge fi lter bags
Section 7.2.1
Please contact Elmo Rietschle Service for other malfunctions or those that cannot be eliminated.