Elmo Rietschle V-VC 50/75/100/150 User Manual
Page 23

23
www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH
|
Maintenance and repair
WARNING
Heavily contaminated air oil removing devices lead
to increased pump temperatures and in extreme
cases may cause the lubricating oil to ignite spon-
taneously.
The oil separator elements (V-VC 50 / 75
➝ 3x, V-VC
100/150
➝ 4x) can become contaminated by dust
particles after they have been running for some time
(power consumption and pump temperature in-
crease). Replace these components (Fig. 7/L) every
2000 operating hours or when the fi lter resistance is
0.7 bar (see pressure gauge
➝ Accessories, Check-
ing with short term, atmospheric suction) because it
is not possible to clean them.
Reduce the change intervals accordingly depending
on how contaminated the discharged medium is.
Changing: Undo the air oil removers (Fig. 7/L) with a
ring spanner (spanner width 19 mm or 3/4”) rotating
counter clockwise. Insert new air oil removers with
the open lock symbol (see Fig. 8) with the arrow
▼
on the insert and fi x turning clockwise (until it clicks
into place).
open
closed
Fig. 8 Air oil remover
7.2.4 Oil removal