Malfunctions: Causes and elimination
8
Malfunctions: Causes and elimination
Fault
Cause
Troubleshooting
Important
Machine is
switched off by
the motor pro-
tection switch
Mains voltage/ Frequency
does not correspond with
the motor data
Check by qualifi ed electrician
Section 5.5
Connection to motor termi-
nal board is not correct
Motor protection switch is
not set correctly
Motor protection switch is
triggered too quickly
Use a motor protection switch with an
overload-dependent delayed switch off
that takes into consideration the short
term excess current at start up (version
with short circuit and overload trigger as
per VDE 0660 Part 2 orIEC 947-4)
The limitation valve or regu-
lation valve (optional extra) is
dirty so that the permissible
pressure is exceeded.
Clean or replace the limitation valve or
regulation valve
Section 7.2
Section 7.4
Blowing ca-
pacity is insuf-
fi cient
The intake fi lter is dirty
Clean or replace the intake fi lter
Sect. 7.2.1 / 7.4
The pressure line is too long
or too narrow
Check the hose or the pipe
Section 5.3
Machine or system leaking
Check the pipework and screw con-
nections for leaks and to ensure that
they are fi rmly seated.
Section 7.2
Blades are damaged
Replace blades
Sect. 7.2.2 / 7.4
Final pressure
(max. excess
pressure)
has not been
reached
Machine or system leaking
Check the pipework and screw con-
nections for leaks and to ensure that
they are fi rmly seated.
Section 7.2
Blades are worn or damaged
Replace blades
Sect. 7.2.2 / 7.4
Machine gets
too hot
Ambient or intake tempera-
ture is too high
Ensure it is being used properly
Section 2.3
Cooling air supply is ob-
structed
Check environmental conditions
Section 5.1
Clean ventilation slots
Section 7.2
The limitation valve or regu-
lation valve (optional extra) is
dirty so that the permissible
pressure is exceeded.
Clean or replace the limitation valve or
regulation valve
Section 7.2
Section 7.4
The machine
makes an ab-
normal noise
The compressor housing is
worn (chatter marks)
Repair by manufacturer or authorised
workshop
Elmo Rietschle
Service
The pressure regulating valve
(if fi tted) is vibrating
Replace the valve
Section 7.4
Blades are damaged
Replace blades
Sect. 7.2.2 / 7.4
Please contact Elmo Rietschle Service for other malfunctions or those that cannot be eliminated.