Elmo Rietschle R-VWP 500/1000/1500/2500 User Manual
Page 33

33
www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH
|
Malfunctions: Causes and elimination
Fault
Cause
Troubleshooting
Important
Pre-pump does
not reach ultimate
vacuum
Machine or system leaking
Check the pipework and
screw connections for leaks
and to ensure that they are
fi rmly seated.
Section 7.2
Machine gets too hot
Ambient or intake temperature
is too high
Ensure it is being used prop-
erly
Section 2.3
Cooling air supply is ob-
structed
Check environmental condi-
tions
Section 5.1
Clean ventilation slots
Section 7.2
Sealing oil degrades
rapidly
Sealing rings and the wear-
ing sleeve of the shaft
feedthrough are worn out
Change sealing rings and the
wearing sleeve of the shaft
feedthrough
Section 7.2.4
The machine makes
a abnormal noise
Deposits on the rotary piston
Clean the working space and
the rotary piston
Elmo Rietschle
Service
The coupling rubbers are
worn
Replace coupling rubbers
Section 7.2.1
Please contact Elmo Rietschle Service for other malfunctions or those that cannot be eliminated.