Elmo Rietschle C-DLR 60/100/120/150/250/300/400/500 User Manual
Page 29

29
www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH
|
Malfunctions: Causes and elimination
Fault
Cause
Troubleshooting
Important
Final pressure (max.
excess pressure) has
not been reached
Machine or system leaking
Check the pipework and
screw connections for leaks
and to ensure that they are
fi rmly seated.
Section 7.2
Driving power selection too
low
Use next largest motor output
Data sheet D
361
Machine gets too hot
Ambient or intake temperature
is too high
Ensure it is being used prop-
erly
Section 2.3
Cooling air supply is ob-
structed
Check environmental condi-
tions
Section 5.1
Clean ventilation slots
Section 7.2
The safety valve is dirty so
that the permissible pressure
is exceeded.
Clean or replace the safety
valve
Section 7.2
Section 7.4
The machine makes
a abnormal noise
Deposits on the rotary piston
Clean the working space and
the rotary piston
Elmo Rietschle
Service
The safety valve is vibrating
Replace the valve
Section 7.4
Please contact Elmo Rietschle Service for other malfunctions or those that cannot be eliminated.