QuickTree
®
settings for ProVore
®
Systems:
When servicing the QuickTree
®
place the switch cord into the trough or channel then slip the stainless steel rod through the clamp and
tighten the screw with a Philips screw driver do not over tighten. Flats have been formed on the rod to designate float positioning the
screw should be tightened onto the flat. The tether length is the amount of cord between the clamp and float.
ROD
POSITION Alarm Float Control Float
1
3.5"
2
3
3.0"
4
P380 & P680
TETHER LENGTH
(SWITCH TO CLAMP)
Float positions 1, 2, 3 and 4
are identified by a “flat”
stamped into the stainless
steel rod. 1 is highest, 4 is
lowest.
Control and alarm floats have different tether
lengths. See above chart for proper tether length
and correct rod position.