INSTALLATION
Make certain that the pump and stand sit level in
the wet well.
Regardless of the installation configuration, the
maximum recommended submergence depth
is 65 feet (20 meters).
After installation in the wet well, reel in any slack in
the cables so that they are not dragged into the
pump suction.
Piping
NOTE
Refer to Pump Performance in OPERATION -
SECTION C when determining the most efficient
piping installation.
No suction piping is required in a standard sub
merged operation.
Either hose or rigid pipe may be used to make dis
charge connections. The discharge line must be
independently supported to avoid vibration and
strain on the pump. For maximum pumping capac
ity, keep the line as short and straight as possible.
Elbows and fittings used in a discharge line in
crease friction losses; minimize their use.
It is recommended that a check valve or throttling
valve be installed in the discharge line to control si
phoning or back flow when the pump is shut off.
ELECTRICAL CONNECTIONS
Install and operate this pump in accor
dance with the National Electrical Code
and all local codes. Have a qualified
electrician perform all checks and con
nections in this section.
Never attempt to alter the length of the
pump motor cable or to repair it with a
splice. The power cable and pump mo
tor must be kept completely waterproof.
Serious damage to the pump and injury
or death to personnel can result from
any alteration to the cable.
Field Wiring Connections (Incoming Power)
Field wiring is not provided with this pump, and
must be supplied by the user. The field wiring must
be of the proper size and type to ensure an ade
quate voltage supply to the pump. Voltage avail
able at the motor must be within the range indi
cated in Table B-2.
TABLE B-2. MOTOR VOLTAGE LIMITS
NOMINAL
VOLTAGE
3
230
207
253
PHASE
MINIMUM
VOLTAGE
MAXIMUM
VOLTAGE
3
460
414
506
3
575
517
632
3
208
187
229
1
230
207
253
Use conduit cable clamps to secure the incoming
field wiring to the control box. Make certain all con
nections are tight. If necessary, support the cable
weight to prevent excessive strain on cable clamps
and cable.
Dual Voltage
230V and 460V versions of these pumps
are dual‐voltage; however, they are
wired at the factory only for the voltage
shown on the nameplate. Do not attempt
to change the voltage in the field. If de
sired to have the voltage changed, re
turn the pump to the factory or to an au
thorized Gorman‐Rupp repair facility
only. Otherwise, damage to the pump
and injury or death to personnel can re
sult.