Pump and seal disassembly and reassembly – Gorman-Rupp Pumps SFV4D 1468407 and up User Manual
Page 31
SF SERIES
OM-06404
MAINTENANCE AND REPAIR
PAGE E - 6
PUMP AND SEAL DISASSEMBLY AND
REASSEMBLY
Review all SAFETY information in Section A.
This pump requires little service due to its rugged,
minimum‐maintenance design. However, if it be
comes necessary to inspect or replace the wearing
parts, follow these instructions, which are keyed to
the illustrations (see Figures E-1 and E-2) and
the corresponding parts lists.
This manual will alert personnel to known proce
dures which require special attention, to those
which could damage equipment, and to those
which could be dangerous to personnel. However,
this manual cannot possibly anticipate and provide
detailed precautions for every situation that might
occur during maintenance of the unit. Therefore, it
is the responsibility of the owner/maintenance per
sonnel to ensure that only safe, established main
tenance procedures are used, and that any proce
dures not addressed in this manual are performed
only after establishing that neither personal safety
nor pump integrity are compromised by such prac
tices.
Do not attempt to service the pump as
sembly unless all power to the motor
has been shut off at the control box;
otherwise, injury or death could result.
Use a lifting device with sufficient ca
pacity. If slings or chains are used to
move the pump or components, make
sure that the load is balanced; other
wise serious personal injury or death
could result.
If this pump is used to handle sewage,
take necessary precautions during
maintenance and repair to prevent per
sonal contamination which could result
in illness.
Select a suitable location, preferably indoors, to
perform required maintenance. All work must be
performed by qualified personnel.
Check the chart in TROUBLESHOOTING, Section
D of this manual, to determine the nature of the
pump problem. If the problem is mechanical in na
ture, such as worn pump parts, seal replacement,
lubrication, etc., refer to PUMP END DISASSEM
BLY for instructions.
If the problem is electrical, complete disassembly
may not be required. Refer to Electrical Testing in
TROUBLESHOOTING, Section D, and have a
qualified electrician check the control box, cable
and terminal housing. If the problem is determined
to be in the cable(s) or terminal housing, see MO
TOR DISASSEMBLY for terminal housing replace
ment. If the problem is determined to be in the mo
tor, proceed with PUMP END DISASSEMBLY, fol
lowed by MOTOR DISASSEMBLY.
The electrical power used to operate
this pump is high enough to cause inju
ry or death. Make certain that the control
handle on the control box is in the off po
sition and locked out, or that the power
supply to the control box has been
otherwise cut off and locked out, before
attempting to open or service the pump
assembly. Tag electrical circuits to pre
vent accidental start‐up.
Carefully inspect any O‐rings before removal and
cleaning to determine if a proper seal and com
pression existed prior to disassembly. If sealing
was faulty or questionable, the cause must be de
termined and corrected before reassembly. All O‐
rings must be replaced if disturbed.
PUMP END DISASSEMBLY
Preparing Pump for Disassembly
Use the hoisting bail to remove the pump from the
wet well or sump, and move it to a suitable location
for disassembly.