Gorman-Rupp Pumps S4C65-E10 460/3 861279 thru 1142084 User Manual
Page 31
CONTROL BOXES
OM--04136
PAGE B -- 25
INSTALLATION
Table 2. Control Box Data Chart
10
60 13.6 513
A999AY523--7
1
27 AMPS
204
H2111B-3
C
9.60/14.4
C0100G6UFB 27521-321
15
60 14.4 534
A999AY523--13
2
45 AMPS
204
H2111B-3
C
9.60/14.4
C0100G6UFB 27521--321
20
60 20.8 534
A999AY523--13
2
45 AMPS
205
H2112B-3
B
14.4/23.8
C0100G6UFB 27521-321
25
60
24
514
A999AY523--10
2
45 AMPS
206
H2113B-3
B
18.7/28.1
C0100G6UFB 27521-321
30
60 30.8 534
A999AY523--13
2
45 AMPS
207
H2114B-3
C/B
23.5/34.8
C0100G6UFB 27521-321
35
60
32
514
A999AY523--10
2
45 AMPS
207
H2114B-3
B
23.5/34.8
C0100G6UFB 27521-321
50
60
50
515
A999AY524--3
3
90 AMPS
210
H2021-3
A
45.7/62.1
C0250G6UFB 27521-321
60
60
52
515
A999AY524--3
3
90 AMPS
210
H2021-3
B
45.7/62.1
C0250G6UFB 27521-321
60
60 52.8 535
A999AY524--7
3
90 AMPS
210
H2021-3
B
45.7/62.1
C0250G6UFB 27521-321
95
60
84
516
A999AY525--3
4
135 AMPS
211
H2022-3
C
62.2/84.6
C0250G6UFB 27521-321
100
60
100 516
A999AY525--3
4
135 AMPS
212
H2023-3
B
84.7/115.0 C0250G6UFB 27521-321
140
60
132 517
A999AY567--6
5
270 AMPS
219
H2106B-3
A
1.92/3.15* C0250G6UFB 27521-321
6.7kw 50 11.5 543
A999AY523-- 8
1
27 AMPS
204
H2111B-3
B
9.60/14.4
C0100G6UFB 27521-321
12kw 50
21
544
A999AY523--11
2
45 AMPS
205
H2112B-3
C
14.4/23.8
C0100G6UFB 27521-321
15kw 50
28
544
A999AY523--11
2
45 AMPS
207
H2114B-3
B
23.5/34.8
C0100G6UFB 27521-321
25kw 50
46
545
A999AY524--4
3
90 AMPS
210
H2021-3
A
45.7/62.1
C0250G6UFB 27521-321
26kw 50
47
545
A999AY524--4
3
90 AMPS
210
H2021-3
A
45.7/62.1
C0250G6UFB 27521-321
41kw 50
76
545
A999AY524--4
3
90 AMPS
211
H2022-3
B
62.2/84.6
C0250G6UFB 27521-321
44kw 50
82
545
A999AY524--4
3
90 AMPS
211
H2022-3
C
62.2/84.6
C0250G6UFB 27521-321
51kw 50
96
546
A999AY525--4
4
135 AMPS
212
H2023-3
B
84.7/115.0 C0250G6UFB 27521-321
65kw 50
115 546
A999AY525--4
4
135 AMPS
213
H2024-3
A
106.0/144.0 C0250G6UFB 27521-321
C-H.
P/N
CONTROL BOX DATA
CONTROL P/N
HEATER PACK NO.
G-R P/N
27515-
RANGE
(AMPS)
CONTROL
TRANS-
FORMER
C-H.
PART NO.
OPTIONAL
LIQ. LEVEL
CONTROL
RELAY
HEATER
SETTING
PUMP DATA**
V
HP
Hz FLA
230
10
60
34
504
A999AY523--9
2
45 AMPS
207
H2114B-3
C
23.5/34.8
C0100G6UFB 27521-321
25
60
60
505
A999AY524--2
3
90 AMPS
210
H2021--3
C
45.7/62.1
C0250G6UFB 27521-321
35
60
80
505
A999AY524--2
3
90 AMPS
211
H2022-3
C
62.2/84.6
C0250G6UFB 27521-321
50
60
124 506
A999AY525--2
4
135 AMPS
213
H2024-3
B
106.0/144.0 C0250G6UFB 27521-321
60
60
130 506
A999AY525--2
4
135 AMPS
213
H2024-3
B
106.0/144.0 C0250G6UFB 27521-321
460
10
60
17
503
A999AY523-6
1
27 AMPS
205
H2112B-3
B
14.4/23.8
C0100G6UFB 27521-321
15
60
17
524
A999AY523-12
2
45 AMPS
205
H2112B-3
B
14.4/23.8
C0100G6UFB 27521-321
20
60
26
524
A999AY523-12
2
45 AMPS
206
H2113B-3
B
18.7/28.1
C0100G6UFB 27521-321
25
60
30
504
A999AY523--9
2
45 AMPS
206
H2113B-3
C
18.7/28.1
C0100G6UFB 27521-321
30
60 38.5 524
A999AY523-2
2
45 AMPS
208
H2115B-3
B
28.3/41.3
C0100G6UFB 27521-321
35
60
40
504
A999AY523--9
2
45 AMPS
208
H2115B-3
B
28.3/41.3
C0100G6UFB 27521-321
50
60
62
505
A999AY524--2
3
90 AMPS
210
H2021-3
C
45.7/62.1
C0250G6UFB 27521-321
60
60
65
505
A999AY524--2
3
90 AMPS
211
H2022-3
A
62.2/84.6
C0250G6UFB 27521-321
60
60
66
525
A999AY524-6
3
90 AMPS
211
H2022-3
A
62.2/84.6
C0250G6UFB 27521-321
95
60
105 506
A999AY525--2
4
135 AMPS
212
H2023-3
C
84.7/115.0 C0250G6UFB 27521-321
100
60
125 506
A999AY525--2
4
135 AMPS
213
H2024-3
B
106.0/144.0 C0250G6UFB 27521-321
140
60
165 507
A999AY567--5
5
270 AMPS
220
H2107B-3
A
2.30/3.77* C0250G6UFB 27521-321
575
380
C.H. P/N
A999AY523
NEMA
SIZE
CONT.
CURRENT
RATING
G-R P/N
2752
1-
HEATER PACK REFERENCE DATA
**
CONSULT INDIVIDUAL PUMP NAME PLATE FOR SPECIFICATIONS.
SEE TABLE 2 FOR 27515--571 AND 27515--572 CONTROL BOX DATA.
200
10
60
39
554
A999AY523--15
2
45 AMPS
208
H2115B-3
C+1/2
28.3/41.3
C0100G6UFB 27521-321
*
CURRENT TRANSFORMER 300:5