Troubleshooting - section d – Gorman-Rupp Pumps PA10A60-4045H 1452219 thru 1484415 User Manual
Page 17
TROUBLE
POSSIBLE CAUSE
PROBABLE REMEDY
PUMP FAILS TO
PRIME
Strainer clogged.
Check strainer and clean if neces-
sary.
Suction lift or discharge head too high.
Check piping installation and install
bypass line if needed. See INSTAL-
LATION.
Leaking or worn seal or pump gasket.
Check pump vacuum. Replace
leaking or worn seal or gasket.
Lining of suction hose collapsed.
Replace suction hose.
Air leak in suction line.
Correct leak.
Discharge check valve contami-
nated, damaged, or unable to seat.
Clean or replace check valve.
PUMP STOPS OR
FAILS TO DELIVER
RATED FLOW OR
PRESSURE
Air leak in suction line.
Correct leak.
Lining of suction hose collapsed.
Replace suction hose.
Leaking or worn seal or pump gasket.
Check pump vacuum. Replace
leaking or worn seal or gasket.
Air compressor head 180
_ out.
Consult factory.
Air compressor damaged or belts bro-
ken.
Check and repair/replace.
Eductor clogged.
Check and clean eductor.
PA SERIES
OM−06344
TROUBLESHOOTING
PAGE D − 1
TROUBLESHOOTING − SECTION D
Review all SAFETY information in Section A.
Before attempting to open or service the
pump:
1. Familiarize yourself with this manual.
2. Shut down the engine and discon-
nect the positive battery cable to en-
sure that the pump will remain inop-
erative.
3. Allow the pump to completely cool if
overheated.
4. Check the temperature and make
sure pump is cool before opening
any covers, plates, or plugs.
5. Close the suction and discharge
valves.
6. Vent the pump slowly and cautiously.
7. Drain the pump.