Gorman-Rupp Pumps PA4A60C-C2.2T 1394774 and up User Manual
Page 49
![background image](/manuals/316012/49/background.png)
OM-06168
PA SERIES
MAINTENANCE & REPAIR
PAGE E - 27
If the orifice button was removed, screw the new
orifice button into the linkage bar until fully seated.
Align the hole in the linkage bar with the holes in the
bracket and reinstall the pivot pin. Secure the pivot
pin with the previously removed “e‐clip”.
Adjust the orifice button seating as necessary by
screwing the orifice button into or out of the linkage
bar. Proper adjustment is achieved when the ori
fice button fully seats against the orifice before the
linkage bar on the float bottoms against the
threads on the orifice button. When adjustment is
complete, install and tighten the lock washer and
hex nut securing the orifice button.
Install the strainer (6) and priming valve gasket (4).
Lower the float into the priming chamber (5) and
secure the priming valve with the previously re
moved hardware (2 and 3).
(Figure 5)
Install the baffle (9) and gasket (8) and use a sling
and suitable lifting device to position the priming
chamber assembly on the hopper spool (32, Fig
ure 3). Secure the priming chamber assembly with
the hardware (6 and 7).
Reconnect the suction piping to the hopper spool
and the air discharge tubing to the priming cham
ber assembly.
LUBRICATION
Seal Assembly
(Figure 5)
Before starting the pump, remove the vented plug
(10) and fill the seal cavity with approximately 5
quarts (4,7 liters) of SAE No. 30 non‐detergent oil
or to the center of the sight gauge (4, Figure 4).
Clean and reinstall the vented plug. Maintain the oil
level at the middle of the sight gauge.
Bearings
(Figure 5)
The bearing housing was fully lubricated when
shipped from the factory. Check the oil level regu
larly through the sight gauge (13)
and maintain it at
the midpoint of the gauge. When lubrication is re
quired, remove the air vent (12) and add SAE No.
30 non‐detergent oil through the opening. When
lubricating a dry (overhauled) intermediate, fill the
bearing cavity with approximately 28 ounces (0,8
liter). Clean and reinstall the air vent. Do not over‐
lubricate. Over‐lubrication can cause the bearings
to over‐heat, resulting in premature bearing failure.
NOTE
The white reflector in the sight gauge must be posi
tioned horizontally to provide proper drainage.
Under normal conditions, drain the bearing hous
ing once each year and refill with clean oil. Change
the oil more frequently if the pump is operated con
tinuously or installed in an environment with rapid
temperature change.
Monitor the condition of the bearing lubri
cant regularly for evidence of rust or mois
ture condensation. This is especially im
portant in areas where variable hot and
cold temperatures are common.
For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.
Engine
Consult the literature supplied with the engine, or
contact your local engine representative.