Gorman-Rupp Pumps PA6C60C-F5L All serial numbers User Manual
Page 45
OM-05770
PA SERIES
MAINTENANCE & REPAIR
PAGE E - 23
(Figure 3)
Use a suitable hoist and sling to position the air
compressor assembly (6) on the mounting flange
(9, Figure 5). Slide the synchronous belt (15) over
the air compressor drive sheave. Use a pry bar to
raise the compressor high enough to install the
spacers (14) between the compressor and the
mounting flange. Secure the compressor to the
mounting flange with the hardware (8, 9 and 10).
Reinstall the guard (7) and secure it with the hard
ware (11, 12 and 13).
Seal Reassembly and Installation
(Figures 5 and 11)
Most cleaning solvents are toxic and
flammable. Use them only in a well ven
tilated area free from excessive heat,
sparks, and flame. Read and follow all
precautions printed on solvent contain
ers.
Clean the seal cavity and shaft with a cloth soaked
in fresh cleaning solvent. Inspect the stationary
seat bore in the seal plate for dirt, nicks and burrs,
and remove any that exist. The stationary seat bore
must be completely clean before installing the
seal.
A new seal assembly should be installed
any time the old seal is removed from the
pump. Wear patterns on the finished faces
cannot be realigned during reassembly.
Reusing an old seal could result in prema
ture failure.
The seal is not normally reused because wear pat
terns on the finished faces cannot be realigned
during reassembly. This could result in premature
failure. If necessary to reuse an old seal in an emer
gency, carefully wash all metallic parts in fresh
cleaning solvent and allow to dry thoroughly.
Handle the seal parts with extreme care to prevent
damage. Be careful not to contaminate precision
finished faces; even fingerprints on the faces can
shorten seal life. If necessary, clean the faces with a
non‐oil based solvent and a clean, lint‐free tissue.
Wipe lightly in a concentric pattern to avoid
scratching the faces.
Inspect the seal components for wear, scoring,
grooves, and other damage that might cause leak
age. Clean and polish the shaft sleeve, or replace it
if there are nicks or cuts on either end. If any com
ponents are worn, replace the complete seal;
never mix old and new seal parts.
If a replacement seal is being used, remove it from
the container and inspect the precision finished
faces to ensure that they are free of any foreign
matter.
To ease installation of the seal, lubricate the shaft
sleeve O‐ring and the external stationary seat O‐
ring with a very small amount of light lubricating oil.
See Figure 10 for seal part identification.