Pump and seal disassembly and reassembly – Gorman-Rupp Pumps PA6C60C-F5L All serial numbers User Manual
Page 38
PA SERIES
OM-05770
MAINTENANCE & REPAIR
PAGE E - 16
PUMP AND SEAL DISASSEMBLY
AND REASSEMBLY
Review all SAFETY information in Section A.
Follow the instructions on all tags, label and de
cals attached to the pump.
This pump requires little service due to its rugged,
minimum‐maintenance design. However, if it be
comes necessary to inspect or replace the wearing
parts, follow these instructions which are keyed to
the illustrations (see Figures 1 through 9) and the
corresponding parts lists. Maintenance and repair
instructions for the air compressor are covered
separately in the specific literature supplied by the
manufacturer.
Some pump service functions may be performed
without separating the pump end assembly from
the engine. However, the priming chamber (2, Fig
ure 3) and discharge check valve assembly (26,
Figure 3) must be removed to service most pump
components. The following instructions assume
complete disassembly of the pump is required.
Before attempting to service the pump, shut down
the engine and take precautions to ensure that it
will remain inoperative. Close all valves in the suc
tion and discharge lines and drain the pump cas
ing by removing the casing drain plug (7C, Figure
4). Clean and reinstall the drain plug.
This manual will alert personnel to
known procedures which require spe
cial attention, to those which could
damage equipment, and to those which
could be dangerous to personnel.
How
ever, this manual cannot possibly antici
pate and provide detailed instructions
and precautions for every situation that
might occur during maintenance of the
unit. Therefore, it is the responsibility of
the owner/maintenance personnel to
ensure that only safe, established main
tenance procedures are used, and that
any procedures not addressed in this
manual are performed only after estab
lishing that neither personal safety nor
pump integrity are compromised by
such practices.
Before attempting to open or service the
pump:
1. Familiarize yourself with this man
ual.
2. Shut down the engine and discon
nect the positive battery cable to
ensure that the pump will remain
inoperative.
3. Allow the pump to completely cool
if overheated.
4. Check the temperature and make
sure it is cool before opening any
covers, plates, gauges, or plugs.
5. Close the suction and discharge
valves.
6. Vent the pump slowly and cau
tiously.
7. Drain the pump.
The pump may be equipped with an au
tomatic starting system, and therefore
subject to automatic restart. Keep
hands and clothing away from the unit to
prevent injury during automatic opera
tion. Disconnect the positive battery
cable before performing any mainte
nance. Failure to do so may result in se
rious personal injury.
Use only replacement parts provided or
approved by Gorman‐Rupp. Use of non‐
authorized parts may result in damage to
the equipment and/or injury to personnel
and will invalidate the warranty.