PA SERIES

OM-05768

MAINTENANCE & REPAIR

PAGE E - 22

Seal Reassembly and Installation

(Figures 5, 10, 11 and 12)

Most cleaning solvents are toxic and
flammable. Use them only in a well ven­
tilated area free from excessive heat,
sparks, and flame. Read and follow all
precautions printed on solvent contain­
ers.

Clean the seal cavity and shaft with a cloth soaked
in fresh cleaning solvent. Inspect the stationary
seat bore in the seal plate for dirt, nicks and burrs,
and remove any that exist. The stationary seat bore
must be completely clean before installing the
seal.

A new seal assembly should be installed
any time the old seal is removed from the
pump. Wear patterns on the finished faces
cannot be realigned during reassembly.

Reusing an old seal could result in prema­
ture failure.

The seal is not normally reused because wear pat­
terns on the finished faces cannot be realigned
during reassembly. This could result in premature
failure. If necessary to reuse an old seal in an emer­
gency, carefully wash all metallic parts in fresh
cleaning solvent and allow to dry thoroughly.

Handle the seal parts with extreme care to prevent
damage. Be careful not to contaminate precision
finished faces; even fingerprints on the faces can
shorten seal life. If necessary, clean the faces with a
non‐oil based solvent and a clean, lint‐free tissue.
Wipe lightly in a concentric pattern to avoid
scratching the faces.

Inspect the seal components for wear, scoring,
grooves, and other damage that might cause leak­
age. Clean and polish the shaft sleeve, or replace it
if there are nicks or cuts on either end. If any com­
ponents are worn, replace the complete seal;
never mix old and new seal parts.

If a replacement seal is being used, remove it from
the container and inspect the precision finished
faces to ensure that they are free of any foreign
matter.

To ease installation of the seal, lubricate the shaft
sleeve O‐ring and the external stationary seat O‐
ring with a very small amount of light lubricating oil.
See Figure 10 for seal part identification.