beautypg.com

Gorman-Rupp Pumps PAH4C60-6068H 1532412 and up User Manual

Page 44

background image

OM-06476

PAH SERIES

MAINTENANCE & REPAIR

PAGE E - 21

Seal Reassembly and Installation

(Figures 5 and 9)

Most cleaning solvents are toxic and
flammable. Use them only in a well ven­
tilated area free from excessive heat,
sparks, and flame. Read and follow all
precautions printed on solvent contain­
ers.

Clean the seal cavity and shaft with a cloth soaked
in fresh cleaning solvent. Inspect the stationary
seat bore in the seal plate for dirt, nicks and burrs,
and remove any that exist. The stationary seat bore

must be completely clean before installing the
seal.

A new seal assembly should be installed
any time the old seal is removed from the
pump. Wear patterns on the finished faces
cannot be realigned during reassembly.
Reusing an old seal could result in prema­
ture failure.

To ease installation of the seal, lubricate the shaft
sleeve O‐ring and the stationary element O‐ring
with a very small amount of light lubricating oil.
See Figure 9 for seal part identification.

SEAL PLATE

O‐RING

IMPELLER

SHAFT

STATIONARY

ELEMENT

ROTATING

ELEMENT

BELLOWS

IMPELLER

SHIMS

IMPELLER

SPRING

RETAINER

SHAFT

SLEEVE

SLEEVE

O‐RING

SPRING

CENTERING

WASHER

SHAFT

KEY

Figure 9. Seal Assembly

This seal is not designed for operation at
temperatures above 160

_

F (71

_

C). Do not

use at higher operating temperatures.

If the seal plate was removed, install the seal plate
gasket (14). Position the seal plate over the shaft
and secure it to the pedestal with the hardware (16
and 17).

Press the stationary element and its O‐ring into the
seal plate until fully seated in the seal plate bore. A
push tube cut from a length of plastic pipe would