suction head. Remove the capscrews from the
suction head.
Pump Casing Removal
(Figure 4)
Remove the uppermost pipe plug (8) from the
pump casing and install a lifting eye in the hole. Be
sure to screw the lifting eye tightly into the hole as
far as it will go. Attach a sling and suitable lifting de
vice to the lifting eye and support the pump casing.
Remove the hardware (1A and 2A) and use the lift
ing device to pull the pump casing straight away
from the rotating assembly (10).
Remove and discard the pump casing O‐ring (5A).
Draining Oil From Seal Cavity
(Figure 5)
If any further disassembly is to be performed on the
pump, the seal oil cavity must be drained to pre
vent the oil in the seal cavity from escaping as the
impeller is removed.
Position a clean container under the seal cavity
drain plug (15B). Remove the plug and drain the oil
from the seal cavity into the container. For shorter
drain time, remove the air vent (12). Clean and rein
stall the drain plug and air vent. Inspect the oil for
water, dirt or a cloudy condition which could indi
cate seal failure.
Impeller Removal
(Figure 5)
With the pump casing removed, use an impact
wrench with a hex key to loosen the impeller caps
crew (1). Remove the capscrew, impeller washer
(2) and roll pin (3).
Use a suitable three‐jawed puller to remove the im
peller (4) and key (26) from the shaft (25). Use cau
tion when removing the impeller; tension on the
shaft seal spring will be released as the impeller is
removed.
NOTE
An alternate method of removing the impeller is to
insert a pair of wedges 180
_ apart between the im
peller and seal plate (10). Tap the wedges evenly in
an alternating pattern to “walk” the impeller off the
shaft.
Remove the impeller adjusting shims (5); tie and
tag the shims, or measure and record their thick
ness for ease of reassembly.
Inspect the impeller and replace if cracked or badly
worn.
Seal Removal
(Figures 5 and 9)
Remove the spring centering washer and seal
spring. Slide the shaft sleeve (7) and rotating por
tion of the seal off the shaft as a unit.
Apply oil to the shaft sleeve and work it up under
the rubber bellows. Slide the rotating portion of the
seal off the shaft sleeve. Remove the shaft sleeve
O‐ring (8).
Use a pair of stiff wires with hooked ends to remove
the stationary element from the seal plate bore.
An alternate method of removing the stationary
seal components is to remove the hardware (16
and 17) and separate the seal plate and gasket
(14) from the pedestal (18). Position the seal plate
on a flat surface with the impeller side down. Use a
wooden dowel or other suitable tool to press on the
back side of the stationary element until the ele
ment and its O‐ring can be removed.
If no further disassembly is required, refer to Seal
Installation.
Separating Pedestal and Drive Assembly
From Engine
(Figure 8)
Support the pedestal using a hoist and sling, and
remove the hardware remove the hardware (6, 7
and 9) securing the drive flange (20, Figure 5) to
the engine bellhousing. Separate the assemblies
by pulling the pedestal straight away from the en
gine.
As the assemblies separate, the flexible portion of
the coupling assembly (3) will remain on the shaft.
To remove the coupling from the shaft, unscrew the
two allen head setscrews from the bushing (2).