PAGE C - 2
a venturi which creates a vacuum in the pump cas
ing in order to fill the suction line and pump casing
with liquid. To prime a pump using an exhaust
primer, open the gas cock in the priming line and
engage the exhaust primer until liquid is thrown out
of the ejector nozzle.
GAS
COCK
HANDLE
Figure 2. Exhaust Primer Assembly
Air can be exhausted to prime a pump by using a
vacuum pump. Either a wet type or a dry type vac
uum pump may be used; however, a wet type is
preferred since it will not be damaged if liquid en
ters it. If a dry vacuum pump is used, provisions
must be made to keep liquid from entering it.
Auxiliary Ejectors
Ejectors function much like exhaust primers. They
may be operated by steam, compressed air, water
or exhaust gases. To prime a pump using an ejec
tor, open the gas cock in the priming line and oper
ate the ejector until liquid is thrown out the ejector
nozzle.
Vacuum Pumps
Air can be exhausted to prime a pump by using a
vacuum pump. Either a wet type or a dry type vac
uum pump may be used; however, a wet type is
preferred since it will not be damaged if liquid en
ters it. If a dry vacuum pump is used, provisions
must be made to keep liquid from entering it.
STARTING
Consult the operations manual furnished with the
power source.
Rotation
The correct direction of pump rotation is counter
clockwise when facing the impeller. If the pump is
operated in the wrong direction, pump perform
ance could be adversely affected, and the pump
could be seriously damaged.
Only operate this pump in the direction in
dicated by the arrow on the pump body
and on the accompanying decal. Other
wise, pump performance could be ad
versely affected, and the pump could be
seriously damaged.
Consult the operating manual furnished with the
power source
before attempting to start the power
source.
If an electric motor is used to drive the pump, re
move V‐belts, couplings, or otherwise disconnect
the pump from the motor before checking motor
rotation. Operate the motor independently while
observing the direction of the motor shaft, or cool
ing fan.
If rotation is incorrect on a three‐phase motor, have
a qualified electrician interchange any two of the
three‐phase wires to change direction. If rotation is
incorrect on a single‐phase motor, consult the lit
erature supplied with the motor for specific instruc
tions.
OPERATION
Leakage
No leakage should be visible at pump mating sur
faces, or at pump connections or fittings. Keep all
line connections and fittings tight to maintain maxi
mum pump efficiency.
Liquid Temperature And Overheating
The maximum liquid temperature for this pump is
160
_ F (71,1_C). Do not apply it at a higher operat
ing temperature.
Overheating can occur if operated with the valves