OM−06120

VGH SERIES

TROUBLESHOOTING

PAGE D − 1

TROUBLESHOOTING − SECTION B

Review all SAFETY information in Section A.

Before attempting to open or service the
pump:
1. Familiarize yourself with this manual.
2. Lock out or disconnect the power

source and take the necessary pre-
cautions to ensure that the pump will
remain inoperative.

3. Allow the pump to completely cool if

overheated.

4. Check the temperature before open-

ing any covers, plates, or plugs.

5. Close the suction and discharge

valves.

6. Vent the pump slowly and cautiously.
7. Drain the pump.

Table D-1 Troubleshooting Chart

TROUBLE

POSSIBLE CAUSE

PROBABLE REMEDY

PUMP FAILS TO PRIME

Auxiliary priming device faulty or im-
properly installed.

Discharge check valve open.

Air leak in suction line.

Lining of suction hose collapsed.

Leaking or worn seal or pump gas-
ket.

Strainer clogged.

Repair priming device or check
installation.

Check position of handle; close
valve.

Correct leak.

Replace suction hose.

Check pump vacuum. Replace leak-
ing or worn seal or gasket.

Check strainer and clean if neces-
sary.

PUMP STOPS OR FAILS
TO DELIVER RATED
FLOW OR PRESSURE

Air leak in suction line.

Lining of suction hose collapsed.

Suction intake not submerged at
proper level or sump too small.

Strainer clogged.

Correct leak.

Replace suction hose.

Check installation and correct sub-
mergence as needed.

Check strainer and clean if neces-
sary.