beautypg.com

Gorman-Rupp Pumps VGH2 1/2D31-B 1379872 thru 1208720 User Manual

Page 18

background image

VGH SERIES

OM−06122

OPERATION

PAGE C − 5

uid from an external source. When handling clean
liquids, flushing liquid is taken from the pump dis-
charge and supplied through the seal flush line
supplied with the pump.

When handling abrasive or tacky liquids, it may be
necessary to supply fresh lubricating liquid from an
external source. Be sure the liquid supplied to the
seal is compatible with the liquid being pumped,
and that its flow is controlled to prevent dilution.
Consult the factory if flushing is required.

Bearings

The bearing housing was not lubricated when
shipped from the factory. See INSTALLATION,
Section B, and lubricate the bearing housing as in-
dicated. Check the constant level oiler regularly
and keep it full of oil. When lubrication is required,
flip the transparent constant level oiler cup open
and fill it with SAE No. 30 non-detergent

oil.

Under normal conditions, drain the bearing hous-
ing once each year and refill with clean oil. Change

the oil more frequently if the pump is operated con-
tinuously or installed in an environment with rapid
temperature change.

Monitor the condition of the bearing lubri-
cant regularly for evidence of rust or mois-
ture condensation. This is especially im-
portant in areas where variable hot and
cold temperatures are common.

For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.

Power Source

Consult the literature supplied with the power
source, or contact your local power source repre-
sentative.