OPERATION --- SECTION C

Review all SAFETY information in Section A.

Follow the instructions on all tags, labels and de-
cals attached to the pump.

Do not attempt to pump any liquids the

pump has not been designed for, and

which may damage the pump or endan-

ger personnel as a result of pump fail-

ure.

Pump speed and operating conditions

must be within the performance range

shown on the curve in Parts Lists manual.

Refer to the pump Specification Data Sheet or the
accompanying Parts List Manual for the specific
performance for your pump.

PRIMING

Install the pump and piping as described in

IN-

STALLATION. Make sure that the piping connec-
tions are tight, and that the pump is securely
mounted. Check that the pump is properly lubri-
cated (see

LUBRICATION in the MAINTENANCE

AND REPAIR manual).

This is not a self-priming pump, so an external
priming device must be used if the pump is in-
stalled on a

suction lift. A foot valve may be in-

stalled at the end of the suction pipe to maintain the
prime; however, this may adversely affect pump
performance due to friction loss. Many standard
centrifugal models are equipped with a hand-oper-
ated vacuum pump, exhaust primer, or ejector for
this purpose. If a priming device was not furnished
with the pump, it may be ordered from the factory
as an option. Before attempting to operate the

priming device, close the discharge throttling
valve. (Installation of a spring-loaded check valve
is also recommended to facilitate priming.) Once
the pump is fully primed, close the valve between
the priming device and pump to preserve the
prime. Start the pump and open the discharge
valve slowly to fill the discharge line. When installed
in a

flooded suction application, simply open the

system valves and permit the incoming liquid to
evacuate the air. After the pump and piping system
have completely filled, evacuate any remaining air
pockets in the pump or suction line.

Never operate the pump unless there is liq-

uid in the pump casing. The pump will not

prime when dry. Extended operation of a

dry pump will destroy the seal assembly.

After filling the pump casing, reinstall

and tighten the fill plug. Do not attempt

to operate the pump unless all connect-

ing piping is securely installed. Other-

wise, liquid in the pump forced out

under pressure could cause injury to

personnel.

Hand Primers

Hand-operated primers are usually mounted on
the pump and, when operated, draw air out of the
suction line and pump casing. To prime a pump
with a hand vacuum pump, open the cock on the
pump priming line. Operate the hand pump until
liquid flows out of the check valve on the bottom of
the primer pump. Once the pump is primed, close
the valve located between the primer and the