INSTALLATION

When checking alignment, disconnect

the power source to ensure that the

pump will remain inoperative.

Adjusting the alignment in one direction

may alter the alignment in another direc-

tion. check each procedure after altering

alignment.

Coupled Drives

When using couplings, the axis of the power
source must be aligned to the axis of the pump
shaft in both the horizontal and vertical planes.
Most couplings require a specific gap or clearance
between the driving and the driven shafts. Refer to
the coupling manufacturer’s service literature.

Align spider insert type couplings by using calipers
to measure the dimensions on the circumference
of the outer ends of the coupling hub every 90_ de-
grees. The coupling is in alignment when the hub
ends are the same distance apart at all points (see
Figure B-3).

Figure B-3. Aligning Spider-Type Couplings

Align non-spider type couplings by using a feeler
gauge or taper gauge between the coupling halves
every 90_. The coupling is in alignment when the
hubs are the same distance apart at all points (see
Figure B-4).

Figure B-4. Aligning Non-Spider Type Couplings

Check parallel adjustment by laying a straightedge
across both coupling rims at the top, bottom, and
side. When the straightedge rests evenly on both
halves of the coupling, the coupling is in horizontal
parallel alignment. If the coupling is misaligned,
use a feeler gauge between the coupling and the
straightedge to measure the amount of misalign-
ment.

V-Belt Drives

When using V-belt drives, the power source and
the pump must be parallel. Use a straightedge
along the sides of the pulleys to ensure that the pul-
leys are properly aligned (see Figure B-5). In drive
systems using two or more belts, make certain that
the belts are a matched set; unmatched sets will
cause accelerated belt wear.

MISALIGNED:

SHAFTS

NOT PARALLEL

MISALIGNED:

SHAFTS

NOT IN LINE

ALIGNED: SHAFTS

PARALLEL AND

SHEAVES IN LINE

Figure B-5. Alignment of V-Belt Driven Pumps

Tighten the belts in accordance with the belt manu-
facturer’s instructions. If the belts are too loose,
they will slip; if the belts are too tight, there will be
excessive power loss and possible bearing failure.