background image

OM-05498

SUPER T SERIES

MAINTENANCE & REPAIR

PAGE E - 12

SEAL PLATE

O‐RINGS

IMPELLER

STATIONARY

STATIONARY

ROTATING

DRIVE BAND

BELLOWS

IMPELLER SHIMS

IMPELLER

SPRING

RETAINER

ELEMENT

ELEMENT

SEAT

SHAFT

ROTATING

Figure 6. 46512-192 Seal Assembly

This seal is not designed for operation at
temperatures above 160

_

F (71

_

C). Do not

use at higher operating temperatures.

Lubricate the stationary seat O‐rings with water or
light oil, and install them in the stationary seat. In­
stall the stationary seal element in the stationary
seat. Press this stationary subassembly into the
front of the seal plate (3) until it seats squarely
against the bore shoulder.

Install the seal plate gasket (4). Position the seal
plate and stationary seat over the shaft and secure
it to the bearing housing (7) with the hardware (5
and 6). Be careful not to damage the stationary
element on the shaft threads.

NOTE

It is recommended that a tapered sleeve be in­
stalled over the threads of the impeller shaft to ease
installation of the rotating seal components.

Lubricate the shaft with water or a small amount of
light oil and slide the rotating subassembly (con­
sisting of the rotating element, bellows and retain­
er) onto the shaft. Apply firm, steady pressure on
the seal retainer as it slides onto the shaft until the
seal faces contact.

Install the seal spring. Lubricate the seal as indi­
cated in LUBRICATION after the impeller is in­
stalled.

Impeller Installation

(Figure 2)

Inspect the impeller, and replace it if cracked or
badly worn. Inspect the impeller and shaft threads
for dirt or damage, and clean or dress the threads
as required.

The shaft and impeller threads must be
completely clean before reinstalling the im­
peller. Even the slightest amount of dirt on