TROUBLESHOOTING
PAGE D - 2
TROUBLE
POSSIBLE CAUSE
PROBABLE REMEDY
PUMP REQUIRES
TOO MUCH POWER
PUMP CLOGS
FREQUENTLY
Impeller or other wearing parts worn
or damaged.
Replace worn or damaged parts.
Check that impeller is properly
centered and rotates freely.
Impeller clogged.
Free impeller of debris.
Pump speed too slow.
Check driver output; check belts
or couplings for slippage.
Discharge head too high.
Install bypass line.
Suction lift too high.
Measure lift w/vacuum gauge. Re
duce lift and/or friction losses in
suction line.
Pump speed too high.
Check driver output; check that
sheaves or couplings are cor
rectly sized.
Discharge head too low.
Adjust discharge valve.
Liquid solution too thick.
Dilute if possible.
Bearing(s) frozen.
Disassemble pump and check
bearing(s).
Liquid solution too thick.
Dilute if possible.
Discharge flow too slow.
Open discharge valve fully to in
crease flow rate, and run power
source at maximum governed
speed.
Suction check valve or foot valve
clogged or binding.
Clean valve.
PUMP STOPS OR
FAILS TO DELIVER
RATED FLOW OR
PRESSURE
Strainer clogged.
Check strainer and clean if neces
sary.
Suction intake not submerged at
proper level or sump too small.
Check installation and correct sub
mergence as needed.
EXCESSIVE NOISE
Cavitation in pump.
Impeller clogged or damaged.
Pump or drive not securely mounted.
Pumping entrained air.
Reduce suction lift and/or friction
losses in suction line. Record vac
uum and pressure gauge readings
and consult local representative or
factory.
Locate and eliminate source of air
bubble.
Secure mounting hardware.
Clean out debris; replace dam
aged parts.