beautypg.com

Troubleshooting - section d – Gorman-Rupp Pumps T3A61S-B /F,/FM User Manual

Page 21

background image

SUPER T SERIES

OM-05264

TROUBLESHOOTING

PAGE D - 1

TROUBLESHOOTING - SECTION D

Review all SAFETY information in Section A.

Before attempting to open or service the
pump:

1. Familiarize yourself with this manual.
2. Lock out or disconnect the power

source to ensure that the pump will
remain inoperative.

3. Allow the pump to completely cool if

overheated.

4. Check the temperature before open­

ing any covers, plates, or plugs.

5. Close the suction and discharge

valves.

6. Vent the pump slowly and cautiously.
7. Drain the pump.

TROUBLE

POSSIBLE CAUSE

PROBABLE REMEDY

PUMP FAILS TO
PRIME

Suction check valve contaminated or
damaged.

Clean or replace check valve.

Air leak in suction line.

Lining of suction hose collapsed.

Correct leak.

Replace suction hose.

Leaking or worn seal or pump gasket.

Check pump vacuum. Replace
leaking or worn seal or gasket.

Suction lift or discharge head too high.

Check piping installation and in­
stall bypass line if needed. See
INSTALLATION.

Strainer clogged.

Check strainer and clean if neces­
sary.

Not enough liquid in casing.

Add liquid to casing. See PRIM­
ING
.