beautypg.com

Gorman-Rupp Pumps 03B51-B 1371962 and up User Manual

Page 12

background image

0 SERIES

OM-01239

PAGE B - 5

INSTALLATION

air from the top of the pump during the priming pro­
cess. This may be accomplished by installing a by­
pass line from the top of the pump, back to the
source of the liquid. The end of the bypass line
must be submerged. The line must be large
enough to prevent clogging, but not so large as to
affect pump discharge capacity.

ALIGNMENT

The alignment of the pump and its power source is
critical for trouble‐free mechanical operation. In
either a flexible coupling or V‐belt driven system,
the driver and pump must be mounted so that their
shafts are aligned with and parallel to each other. It
is imperative that alignment be checked after the
pump and piping are installed, and before opera­
tion.

NOTE

Check Rotation, Section C, before final alignment
of the pump.

When mounted at the Gorman‐Rupp factory, driver
and pump are aligned before shipment. Misalign­
ment will occur in transit and handling. Pumps
must be checked and realigned before operation.
Before checking alignment, tighten the foundation
bolts. The pump casing feet and/or pedestal feet,
and the driver mounting bolts should also be tightly
secured.

When checking alignment, disconnect
the power source to ensure that the
pump will remain inoperative.

Adjusting the alignment in one direction
may alter the alignment in another direc­
tion. check each procedure after altering
alignment.

Coupled Drives

When using couplings, the axis of the power
source must be aligned to the axis of the pump
shaft in both the horizontal and vertical planes.
Most couplings require a specific gap or clearance
between the driving and the driven shafts. Refer to
the coupling manufacturer's service literature.

Align spider insert type couplings by using calipers
to measure the dimensions on the circumference
of the outer ends of the coupling hub every 90

_.

The coupling is in alignment when the hub ends
are the same distance apart at all points (see Fig­
ure 3).

Figure 3. Aligning Spider‐Type Couplings

Figure 4. Aligning Non‐Spider Type

Couplings

Align non‐spider type couplings by using a feeler
gauge or taper gauge between the coupling halves
every 90

_. The coupling is in alignment when the

hubs are the same distance apart at all points (see
Figure 4).

Check parallel adjustment by laying a straightedge
across both coupling rims at the top, bottom, and
side. When the straightedge rests evenly on both
halves of the coupling, the coupling is in horizontal
parallel alignment. If the coupling is misaligned,
use a feeler gauge between the coupling and the