beautypg.com

Gorman-Rupp Pumps 03H1-B 710816 and up User Manual

Page 29

background image

0 SERIES

OM-01192

MAINTENANCE & REPAIR

PAGE E - 10

Final Pump Assembly

Be sure the pump and power source are securely
mounted to the base.

Install the suction and discharge lines and open all
valves. Make certain that all piping connections are
tight, properly supported and secure.

Be sure the pump, pedestal and power source
have been properly lubricated, see LUBRICA­
TION
.

Fill the pump casing with clean liquid. Reinstall the
fill plug (49) and tighten it.

Refer to OPERATION, Section C, before putting
the pump back into service.

LUBRICATION

Seal Assembly

The seal assembly is lubricated by the medium be­
ing pumped and no additional lubrication is re­
quired.

Bearings

The pedestal was fully lubricated when shipped
from the factory. Check the oil level regularly

through the sight gauge (27)

and maintain it at the

middle of the gauge. When lubrication is required,
add SAE No. 30 non‐detergent

oil through the hole

for the air vent (15). Do not over‐lubricate. Over‐lu­
brication can cause the bearings to over‐heat, re­
sulting in premature bearing failure.

NOTE

The white reflector in the sight gauge must be posi­
tioned horizontally to provide proper drainage.

Under normal conditions, drain the bearing hous­
ing once each year and refill with clean oil. Change
the oil more frequently if the pump is operated con­
tinuously or installed in an environment with rapid
temperature change.

Monitor the condition of the bearing lubri­
cant regularly for evidence of rust or mois­
ture condensation. This is especially im­
portant in areas where variable hot and
cold temperatures are common.

For cold weather operation, consult the factory for
the recommended grade of oil.