Gorman-Rupp Pumps 03H1-B 710816 and up User Manual
Page 29
0 SERIES
OM-01192
MAINTENANCE & REPAIR
PAGE E - 10
Final Pump Assembly
Be sure the pump and power source are securely
mounted to the base.
Install the suction and discharge lines and open all
valves. Make certain that all piping connections are
tight, properly supported and secure.
Be sure the pump, pedestal and power source
have been properly lubricated, see LUBRICA
TION.
Fill the pump casing with clean liquid. Reinstall the
fill plug (49) and tighten it.
Refer to OPERATION, Section C, before putting
the pump back into service.
LUBRICATION
Seal Assembly
The seal assembly is lubricated by the medium be
ing pumped and no additional lubrication is re
quired.
Bearings
The pedestal was fully lubricated when shipped
from the factory. Check the oil level regularly
through the sight gauge (27)
and maintain it at the
middle of the gauge. When lubrication is required,
add SAE No. 30 non‐detergent
oil through the hole
for the air vent (15). Do not over‐lubricate. Over‐lu
brication can cause the bearings to over‐heat, re
sulting in premature bearing failure.
NOTE
The white reflector in the sight gauge must be posi
tioned horizontally to provide proper drainage.
Under normal conditions, drain the bearing hous
ing once each year and refill with clean oil. Change
the oil more frequently if the pump is operated con
tinuously or installed in an environment with rapid
temperature change.
Monitor the condition of the bearing lubri
cant regularly for evidence of rust or mois
ture condensation. This is especially im
portant in areas where variable hot and
cold temperatures are common.
For cold weather operation, consult the factory for
the recommended grade of oil.