0 SERIES

OM-01186

TROUBLESHOOTING

PAGE D - 1

TROUBLESHOOTING - SECTION D

Review all SAFETY information in Section A.

Before attempting to open or service the
pump:

1. Familiarize yourself with this manual.
2. Disconnect or lock out the power

source to ensure that the pump will
remain inoperative.

3. Allow the pump to completely cool if

overheated.

4. Check the temperature before open­

ing any covers, plates, or plugs.

5. Close the suction and discharge

valves.

6. Vent the pump slowly and cautiously.
7. Drain the pump.

TROUBLE

POSSIBLE CAUSE

PROBABLE REMEDY

PUMP FAILS TO
PRIME

PUMP STOPS OR
FAILS TO DELIVER
RATED FLOW OR
PRESSURE

Not enough liquid in casing.

Add liquid to casing. See PRIMING.

Suction check valve contaminated

Clean or replace check valve.

or damaged.

Air leak in suction line.

Correct leak.

Lining of suction hose collapsed.

Replace suction hose.

Leaking or worn seal or pump gasket.

Check pump vacuum. Replace
leaking or worn seal or gasket.

Suction lift or discharge head too high.

Check piping installation and
install bypass line if needed. See
INSTALLATION.

Strainer clogged.

Check strainer and clean if
necessary.

Suction check valve or foot valve

Clean valve.

clogged or binding.

Air leak in suction line.

Correct leak.

Lining of suction hose collapsed.

Replace suction hose.

Leaking or worn seal or pump gasket.

Check pump vacuum. Replace
leaking or worn seal or gasket.

Strainer clogged.

Check strainer and clean if
necessary.