beautypg.com

Gorman-Rupp Pumps 06B52-B 1332442 and up User Manual

Page 26

background image

OM-01229

0 SERIES

MAINTENANCE & REPAIR

PAGE E - 7

INSTALLATION OF NEW DEPARTURE OR

BCA/FEDERAL MOGAL 5300W SERIES BEARINGS

(OPEN OR ENCLOSED IMPELLERS)

INSTALLATION OF MRC/SKF 5300M OR

FAFNIR 5300W SERIES BEARINGS

(OPEN OR ENCLOSED IMPELLERS)

LOADING

DIRECTION OF

THRUST

BALL LOADING

GROOVE POSITIONED

AWAY FROM IMPELLER

GROOVE

DIRECTION OF

THRUST

LOADING

BALL LOADING

GROOVE POSITIONED

TOWARD IMPELLER

GROOVE

Figure 2. Inboard Bearing Positioning

Heat the bearings to a uniform temperature no
higher than
250

_F (120_C), and slide the bearings

onto the shaft, one at a time, until they are fully
seated. This should be done quickly, in one con­
tinuous motion, to prevent the bearings from cool­
ing and sticking on the shaft.

Use caution when handling hot bear­
ings to prevent burns.

After the bearings have been installed and allowed
to cool, check to ensure that they have not moved
away from the shaft shoulders in shrinking. If
movement has occurred, use a suitably sized
sleeve and a press to reposition the bearings
against the shaft shoulders.

If heating the bearings is not practical, use a suit­
ably sized sleeve and an arbor (or hydraulic) press
to install the bearings on the shaft.

When installing the bearings onto the
shaft, never press or hit against the outer
race, balls, or ball cage. Press only on the
inner race.

Lubricate the lip seal area of the shaft, and slide the
shaft and assembled bearings into the pedestal

until the inboard bearing seats against the inboard
bearing cap.

When installing the shaft and bearings into
the bearing bore, push against the outer
race. Never hit the balls or ball cage.

Press the oil seal (21) into the bearing cap (20) with
the lip positioned as shown in Figure 1. The face of
the oil seal should be flush with the outside of the
bearing cap.

Install the same thickness of bearing adjusting
shims (26) as previously removed. Install the bear­
ing cap gasket (18) and secure the bearing cap to
the pedestal with the hardware (19). Be careful
not to damage the oil seal lip on the shaft keyway.

Shaft endplay should be between .002 and .010
inch (0,05 to 0,25 mm). Check the shaft endplay
and add or remove bearing adjusting shims as re­
quired.

Install slinger ring (13).

Lubricate the bearing housing as indicated in LU­
BRICATION
.

Seal Reassembly and Installation

(Figures 1 and 3)

Clean the seal cavity and shaft with a cloth soaked
in fresh cleaning solvent.