Gorman-Rupp Pumps 02D3-X1.5 3P 254341 and up User Manual
Page 6
0 SERIES
OM-01122
PAGE A - 1
SAFETY
SAFETY - SECTION A
This information applies to 0 Series
electric motor driven pumps. Refer to
the manual accompanying the motor
before attempting to begin operation.
This manual will alert personnel to
known procedures which require spe
cial attention, to those which could
damage equipment, and to those which
could be dangerous to personnel. How
ever, this manual cannot possibly pro
vide detailed instructions and precau
tions for each specific application or for
every situation that might occur during
maintenance of the unit. Therefore, it is
the responsibility of the owner, installer
and/or maintenance personnel to en
sure that applications and/or mainte
nance procedures not addressed in this
manual are performed only after estab
lishing that neither personal safety nor
pump integrity are compromised by
such applications or procedures.
Before attempting to open or service the
pump:
1. Familiarize yourself with this man
ual.
2. Disconnect the incoming power to
the motor and lock it out to ensure
that the pump will remain inopera
tive.
3. Allow the pump to completely cool
if overheated.
4. Check the temperature before
opening any covers, plates, or
plugs.
5. Close the suction and discharge
valves.
6. Vent the pump slowly and cau
tiously.
7. Drain the pump.
This pump is designed to handle petro
leum products or other industrial liq
uids that do not contain large entrained
solids. Do not attempt to pump volatile,
corrosive, or flammable materials which
may damage the pump or endanger per
sonnel as a result of pump failure.
This pump is designed to handle petro
leum products or other industrial liq
uids that do not contain large entrained
solids. All controls must meet industry
standards and codes for use in an ex
plosive atmosphere. Do not attempt to
pump liquids for which the pump and/or
controls have not been approved, or
which may damage the pump or endan
ger personnel as a result of pump fail
ure.
Be certain proper safety practices are
followed before operating or servicing
the pump. Provide adequate ventilation,
prohibit smoking, wear static‐resistant
clothing and shoes. Clean up all fuel
spills immediately after occurrence.
Do not install and operate a non‐explo
sion proof motor in an explosive atmo
sphere. Install, connect, and operate
the motor in accordance with the Na
tional Electric Code and all local codes.
If there is a conflict between the instruc
tions in the manual accompanying the
unit and the National Electric Code or