Pump and seal disassembly and reassembly – Gorman-Rupp Pumps 16A20-B 818301 and up User Manual
Page 27
10 SERIES
OM‐00710
MAINTENANCE & REPAIR
PAGE E - 4
PUMP AND SEAL DISASSEMBLY
AND REASSEMBLY
Review all SAFETY information in Section A.
Follow the instructions on all tags, label and de
cals attached to the pump.
This pump requires little service due to its rugged,
minimum‐maintenance design. However, if it be
comes necessary to inspect or replace the wearing
parts, follow these instructions which are keyed to
the sectional view (see Figure 1) and the accompa
nying parts list.
This manual will alert personnel to known proce
dures which require special attention, to those
which could damage equipment, and to those
which could be dangerous to personnel. However,
this manual cannot possibly anticipate and provide
detailed precautions for every situation that might
occur during maintenance of the unit. Therefore, it
is the responsibility of the owner/maintenance per
sonnel to ensure that only safe, established main
tenance procedures are used, and that any proce
dures not addressed in this manual are performed
only after establishing that neither personal safety
nor pump integrity are compromised by such prac
tices.
Before attempting to service the pump, disconnect
or lock out the power source to ensure that the
pump will remain inoperative. Close all valves in the
suction and discharge lines.
For power source disassembly and repair, consult
the literature supplied with the power source, or
contact your local power source representative.
Before attempting to open or service the
pump:
1. Familiarize yourself with this man
ual.
2. Disconnect or lock out the power
source to ensure that the pump will
remain inoperative.
3. Allow the pump to completely cool
if overheated.
4. Check the temperature before
opening any covers, plates, or
plugs.
5. Close the suction and discharge
valves.
6. Vent the pump slowly and cau
tiously.
7. Drain the pump.
Death or serious personal injury and
damage to the pump or components
can occur if proper lifting procedures
are not observed. Make certain that
hoists, chains, slings or cables are in
good working condition and of suffi
cient capacity and that they are posi
tioned so that loads will be balanced
and the pump or components will not be
damaged when lifting. Suction and dis
charge hoses and piping must be re
moved from the pump before lifting. Lift
the pump or component only as high as
necessary and keep personnel away
from suspended objects.
Suction Check Valve Removal and
Disassembly
Before attempting to service the pump, remove the
pump casing drain plug (68) and drain the pump.
Clean and reinstall the drain plug.
The check valve assembly (81) may be serviced by
removing the suction flange (79). To remove the
flange, disconnect the suction piping. Disengage
the hardware (77 and 78) and separate the suction
flange from the check valve seat (75). Remove the
machine screws (80), and pull the seat and as
sembled check valve from the suction port. Pull the
check valve out of the seat.
Inspect the check valve components for wear or
damage. If replacement is required, disengage the
hardware (82 and 83) and separate the valve
weights (84 and 86) and gasket (85).
Replace the flange gaskets (74 and 76) as re
quired.
If no further disassembly is required, see Suction
Check Valve Installation.