Gorman-Rupp Pumps 11 1/2A2-E2 1P 1046838 and up User Manual
Page 15
OM-04092
10 SERIES
PAGE B - 8
INSTALLATION
ELECTRICAL CONNECTIONS
Before connecting the motor to the incoming
power, check that the electrical service available
matches the pump motor requirements stamped
on the motor nameplate.
The electrical power used to operate
this pump is high enough to cause inju
ry or death. Obtain the services of a qu
alified electrician to make all electrical
connections.
Do not install and operate a non‐explo
sion proof motor in an explosive atmo
sphere. Install, connect, and operate
the motor in accordance with The Na
tional Electric Code and all local codes.
If there is a conflict between the instruc
tions in the manual accompanying the
unit and The National Electric Code or
the applicable local code, The National
or local code shall take precedence.
Refer to the following motor data before making
electrical connections.
VOLTAGE
PHASE
HP
Hz
RPM
THERMAL
OVERLOAD
115/230
230/460
1
3
2
2
60
60
3450
3450
20 AMPS
N/A