Gorman-Rupp Pumps 11 1/2A3-B 348418 and up User Manual
Page 34
OM-00565
10 SERIES
MAINTENANCE & REPAIR
PAGE E - 11
Bearings
The pedestal was fully lubricated when shipped
from the factory. Under normal conditions, remove
the vented plug (15) and add one shot of No. 0 lithi
um base grease from a grease gun after each 250
hours of operation or once each month, whichever
comes first. Do not over lubricate. Over lubrication
can cause the bearings to over heat, resulting in
premature bearing failure.
There are no provisions in the bearing cavity to
drain or flush the lubricant. The pump and pedestal
must be disassembled to completely clean and
maintain this cavity.
Under normal conditions, change the grease after
each 5000 hours of operation, or at 12 month inter
vals, whichever comes first. Change the grease
more frequently if the pump is operated continu
ously or installed in an environment where variable
hot and cold temperatures are common.
When lubricating a dry (overhauled) pedestal, fill
the cavity with approximately 1.5 ounces (43
grams) of grease.
Monitor the condition of the bearing lubri
cant regularly for evidence of rust or mois
ture condensation. This is especially im
portant in areas where variable hot and
cold temperatures are common.
Power Source
Consult the literature supplied with the power
source, or contact your local power source repre
sentative.