Gorman-Rupp Pumps 11 1/2A3-B 348418 and up User Manual
Page 28
OM-00565
10 SERIES
MAINTENANCE & REPAIR
PAGE E - 5
Pump Casing Removal
Death or serious personal injury and
damage to the pump or components
can occur if proper lifting procedures
are not observed. Make certain that
hoists, chains, slings or cables are in
good working condition and of suffi
cient capacity and that they are posi
tioned so that loads will be balanced
and the pump or components will not be
damaged when lifting. Suction and dis
charge hoses and piping must be re
moved from the pump before lifting. Lift
the pump or component only as high as
necessary and keep personnel away
from suspended objects.
To service the impeller (2), wear plate assembly
(27) and seal assembly (3), disconnect the dis
charge piping. Remove the hardware securing the
pump casing (1) to the base. Disconnect the power
source. Tie and tag any leveling shims used under
the pump mounting feet to ease reassembly.
Remove the nuts (11) securing the pump casing
and gasket set (26) to the pedestal (24) and seal
plate (25). Separate the casing from the seal plate
and pedestal.
Remove the gasket set (26) from the pedestal and
seal plate. Clean the mating surfaces of the seal
plate and pump casing. Tie and tag the gaskets, or
measure and record their thickness for ease of
reassembly. Tie and tag any leveling shims used
under the casing mounting feet to ease reassemb
ly.
Impeller Removal
Immobilize the impeller by wedging a block of
wood between the vanes. If removed, install the
shaft key (19). Install a lathe dog on the drive end of
the shaft (20) with the “V” notch positioned over the
shaft keyway.
With the impeller rotation still blocked, strike the
lathe dog sharply in a counterclockwise direction
(when facing the drive end of the shaft). The impel
ler may also be loosened by using a long piece of
heavy bar stock to pry against the arm of the lathe
dog in a counterclockwise direction (when facing
the drive end of the shaft) as shown in Figure 2.
Use caution not to damage the shaft or keyway.
When the impeller breaks loose, remove the lathe
dog and wood block and unscrew the impeller
from the shaft.
Turn
Counterclockwise
Lathe Dog Arm
“V” Notch
Shaft Key
Impeller Shaft
Lathe Dog
Setscrew
Heavy
Bar Stock
Figure 2. Loosening Impeller
Unscrew the impeller in a counterclockwise direc
tion. Use caution when removing the impeller; ten
sion on the seal spring will be released as the im
peller is unscrewed.
Inspect the impeller and replace it if cracked or
badly worn. Slide the impeller adjusting shims (22)
off the impeller shaft. Tie and tag the shims or mea
sure and record their thickness for ease of reas
sembly.
Seal Removal and Disassembly
Remove the spring centering washer (21) and the
seal spring. Slide the shaft sleeve (23) and rotating
portion of the seal off the shaft as a single unit. Ap
ply oil to the sleeve and work it up under the bel
lows. Slide the rotating portion of the seal off the
shaft.
Slide the seal plate and seal assembly off the shaft
as a single unit. Place the seal plate on a flat sur
face with the impeller side down. Use a suitably
sized dowel to press the seal components from the
seal plate.