beautypg.com

Gorman-Rupp Pumps 13A2-B 710664 and up User Manual

Page 34

background image

OM-00621

10 SERIES

MAINTENANCE & REPAIR

PAGE E - 11

GREASE

FITTING

CROSS

ARM

POSITION

WHEN

EMPTY

POSITION

FOR

FILLING

POSITION

WHEN

IN USE

RELIEF

HOLE

Figure 4. Automatic Lubricating Grease Cup

Bearings

The pedestal was fully lubricated when shipped
from the factory. Check the oil level regularly
through the sight gauge (26) and maintain it at the
middle of the gauge. When lubrication is required,
add SAE No. 30 non‐detergent oil through the hole
for the air vent (14). Do not over‐lubricate. Over‐lu­
brication can cause the bearings to over‐heat, re­
sulting in premature bearing failure.

Under normal conditions, drain the pedestal once
each year and refill with clean oil to the middle of
the sight gauge. Change the oil more frequently if
the pump is operated continuously or installed in
an environment with rapid temperature change.

Monitor the condition of the bearing lubri­
cant regularly for evidence of rust or mois­
ture condensation. This is especially im­
portant in areas where variable hot and
cold temperatures are common.

For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.

Power Source

Consult the literature supplied with the power
source, or contact your local power source repre­
sentative.