leveling shims used under the mounting feet of the
pump casing.
Back Cover Installation
If the wear plate (33) was removed for replace
ment, secure it to the cover plate (43) using the at
taching hardware (36 and 37) at this time. The wear
plate must be concentric to prevent binding when
the back cover is installed.
Clean any scale or debris from the contacting sur
faces on the pump casing that might prevent a
good seal with the back cover. Replace the back
cover gasket (39) and slide the back cover assem
bly into the pump casing. Be sure the wear plate
does not bind against the impeller.
NOTE
To ease future disassembly, apply a film of grease
or `Never‐Seez' on the back cover shoulder, or any
surface that contacts the pump casing. This action
will reduce rust and scale build‐up.
Secure the back cover assembly by installing the
clamp bar (45) and tightening the clamp bar screw
(46). Do not over‐tighten the clamp bar screw; it
should be just tight enough to seal the back cover
shoulder.
Suction Check Valve Installation
Inspect components of the check valve assembly
(51) and replace as required. If separated at disas
sembly, assemble the check valve weights (53 and
56) to the check valve gasket (52) with the hard
ware (54 and 55).
Position the check valve assembly in the suction
port with the large weight toward the inside of the
pump casing. Install the suction flange (58) and se
cure with the hardware (49 and 50). Check the op
eration of the check valve to ensure proper seating
and free movement.
Final Pump Assembly
Be sure the pump and power source are securely
mounted to the base. Reconnect the power source
to the pump.
Install the suction and discharge lines and open all
valves. Make certain that all piping connections are
tight, properly supported and secure.
If a lifting eye was used to move the pump casing,
be sure to remove the lifting eye from the pump
casing.
Be sure the pump and power source have been
properly lubricated, see LUBRICATION.
Fill the pump casing with clean liquid. Reinstall the
fill plug (5) and tighten it.
Refer to OPERATION, Section C, before putting
the pump back into service.
LUBRICATION
Seal Assembly
(Figures 1 and 4)
Fill the grease cup (8) through the grease fitting
with No. 2 lithium base grease until grease es
capes from the relief hole. Turn the grease cup arm
counterclockwise until it is at the top of the stem;
this will release the spring to apply grease to the
seal (see Figure 4).