Pump and seal disassembly and reassembly – Gorman-Rupp Pumps 13C2-B 715157 and up User Manual
Page 26
OM-00638
10 SERIES
MAINTENANCE & REPAIR
PAGE E - 4
PUMP AND SEAL DISASSEMBLY
AND REASSEMBLY
Review all SAFETY information Section A.
Follow the instructions on all tags, label and de
cals attached to the pump.
This pump requires little service due to its rugged,
minimum‐maintenance design. However, if it be
comes necessary to inspect or replace the wearing
parts, follow these instructions which are keyed to
the sectional view (see Figure E-1) and the ac
companying parts list.
This manual will alert personnel to known proce
dures which require special attention, to those
which could damage equipment, and to those
which could be dangerous to personnel. However,
this manual cannot possibly anticipate and provide
detailed precautions for every situation that might
occur during maintenance of the unit. Therefore, it
is the responsibility of the owner/maintenance per
sonnel to ensure that only safe, established main
tenance procedures are used, and that any proce
dures not addressed in this manual are performed
only after establishing that neither personal safety
nor pump integrity are compromised by such prac
tices.
Before attempting to service the pump, lock out or
disconnect the power source to ensure that it will
remain inoperative. Close all valves in the suction
and discharge lines.
For power source disassembly and repair, consult
the literature supplied with the power source, or
contact your local power source representative.
Before attempting to open or service the
pump:
1. Familiarize yourself with this man
ual.
2. Lock out or disconnect the power
source to ensure that the pump will
remain inoperative.
3. Allow the pump to completely cool
if overheated.
4. Check the temperature before
opening any covers, plates, or
plugs.
5. Close the suction and discharge
valves.
6. Vent the pump slowly and cau
tiously.
7. Drain the pump.
Death or serious personal injury and
damage to the pump or components
can occur if proper lifting procedures
are not observed. Make certain that
hoists, chains, slings or cables are in
good working condition and of suffi
cient capacity and that they are posi
tioned so that loads will be balanced
and the pump or components will not be
damaged when lifting. Suction and dis
charge hoses and piping must be re
moved from the pump before lifting. Lift
the pump or component only as high as
necessary and keep personnel away
from suspended objects.
Back Cover Removal
Before attempting to service the pump, remove the
pump casing drain plug (34) and drain the pump.
Clean and reinstall the drain plug.
The wear plate assembly (33) is easily accessible
and may be serviced by removing the back cover
assembly (36). Loosen the clamp bar screw (41)
and remove the clamp bar (43). Pull the back cover
and wear plate from the pump casing. Remove the
back cover gasket (35). Clean the mating surfaces
of the back cover plate and pump casing.
Inspect the wear plate and replace it if badly scored
or worn. To remove the wear plate, disengage the
hardware (44 and 45) securing it to the back cover.
If no further disassembly is required, see Back
Cover Installation.