beautypg.com

Gorman-Rupp Pumps 13C20-B 710764 and up User Manual

Page 34

background image

10 SERIES

OM-00641

MAINTENANCE & REPAIR

PAGE E - 10

in the mounting slot in the suction flange (52). Align
the adaptor with the flange hole and secure the as­
sembly with the check valve pin (60).

Back Cover Installation

If the wear plate (37) was removed for replace­
ment, secure it to the cover plate (44) using the at­
taching hardware (48 and 49) at this time. The wear
plate must be concentric to prevent binding when
the back cover is installed.

Clean any scale or debris from the contacting sur­
faces on the pump casing that might prevent a
good seal with the back cover. Replace the back
cover gasket (39) and slide the back cover assem­
bly into the pump casing. Be sure the wear plate
does not bind against the impeller.

NOTE

To ease future disassembly, apply a film of grease
or `Never‐Seez' on the back cover shoulder, or any
surface that contacts the pump casing. This action
will reduce rust and scale build‐up.

Secure the back cover assembly by installing the
clamp bar (47) and tightening the clamp bar screw
(45). Do not over‐tighten the clamp bar screw; it
should be just tight enough to seal the back cover
shoulder.

Final Pump Assembly

Secure the pump to the base with the previously re­
moved hardware. Be sure to reinstall any leveling
shims used under the pump casing or pedestal
mounting feet. Install the shaft key (21) and con­
nect the power source.

Be sure the pump and power source are securely
mounted to the base.

Install the suction and discharge lines and open all
valves. Make certain that all piping connections are
tight, properly supported and secure. Open all the
valves in the suction and discharge lines.

Be sure the pump and power source have been
properly lubricated, see LUBRICATION.

Remove the fill plug assembly (7) and fill the pump
casing with clean liquid. Reinstall the fill plug and
tighten it.

Refer to OPERATION, Section C, before putting
the pump back into service.

LUBRICATION

Seal Assembly

Fill the bottle oiler (8) with SAE No. 30 non‐deterg­
ent oil. Check the oil level regularly and keep the
bottle oiler full.

Bearings

The pedestal was fully lubricated when shipped
from the factory. Check the oil level regularly
through the sight gauge (26) and maintain it at the
middle of the gauge. When lubrication is required,
add SAE No. 30 non‐detergent oil through the hole
for the air vent (14). Do not over‐lubricate. Over‐lu­
brication can cause the bearings to over‐heat, re­
sulting in premature bearing failure.

Under normal conditions, drain the pedestal once
each year and refill with clean oil to the middle of
the sight gauge. Change the oil more frequently if
the pump is operated continuously or installed in
an environment with rapid temperature change.

Monitor the condition of the bearing lubri­
cant regularly for evidence of rust or mois­
ture condensation. This is especially im­
portant in areas where variable hot and
cold temperatures are common.

For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.

Power Source

Consult the literature supplied with the power
source, or contact your local power source repre­
sentative.