beautypg.com

Gorman-Rupp Pumps 13C20-B 710764 and up User Manual

Page 15

background image

OM-00641

10 SERIES

PAGE B - 8

INSTALLATION

Connect the valve outlet to a bleed line which
slopes back to the wet well or sump. The bleed line
must be the same size as the outlet opening or
larger, depending on which Air Release Valve is be­
ing used. If piping is used for the bleed line, avoid
the use of elbows whenever possible.

NOTE

For multiple pump installations, it is recommended
that each Air Release Valve be fitted with an inde­
pendent bleeder line directed back to the wet well.
If multiple Air Release Valves are installed in a sys­
tem, do not direct bleeder lines to a common mani­
fold pipe. Contact your Gorman‐Rupp distributor or
the Gorman‐Rupp Company for information about
installation of an Automatic Air Release Valve for
your specific application.

ALIGNMENT

The alignment of the pump and its power source is
critical for trouble‐free mechanical operation. In
either a flexible coupling or V‐belt driven system,
the driver and pump must be mounted so that their
shafts are aligned with and parallel to each other. It
is imperative that alignment be checked after the
pump and piping are installed, and before opera­
tion.

NOTE

Check Rotation, Section C, before final alignment
of the pump.

When mounted at the Gorman‐Rupp factory, driver
and pump are aligned before shipment. Misalign­
ment will occur in transit and handling. Pumps
must be checked and realigned before operation.
Before checking alignment, tighten the foundation
bolts. The pump casing feet and/or pedestal feet,
and the driver mounting bolts should also be tightly
secured.

When checking alignment, disconnect
the power source to ensure that the
pump will remain inoperative.

Adjusting the alignment in one direction
may alter the alignment in another direc­
tion. Check each procedure after altering
alignment.

Coupled Drives

When using couplings, the axis of the power
source must be aligned to the axis of the pump
shaft in both the horizontal and vertical planes.
Most couplings require a specific gap or clearance
between the driving and the driven shafts. Refer to
the coupling manufacturer's service literature.

Align spider insert type couplings by using calipers
to measure the dimensions on the circumference
of the outer ends of the coupling hub every 90

_

.

The coupling is in alignment when the hub ends
are the same distance apart at all points (see Fig­
ure 4A).

Figure 4A. Alignment of V‐Belt Driven Pumps

Align non‐spider type couplings by using a feeler
gauge or taper gauge between the coupling halves
every 90

_

. The coupling is in alignment when the

hubs are the same distance apart at all points (see
Figure 4B).