10 SERIES
OM−00725
MAINTENANCE & REPAIR
PAGE E − 16
Bearings
(Figure 2)
The intermediate was fully lubricated when
shipped from the factory. Check the oil level regu-
larly through the sight gauge (34)
and maintain it at
the middle of the gauge. When lubrication is re-
quired, add SAE No. 30 non-detergent oil through
the hole for the oil hole cover (20). Do not over-lu-
bricate. Over-lubrication can cause the bearings to
over-heat, resulting in premature bearing failure.
NOTE
The white reflector in the sight gauge must be posi-
tioned horizontally to provide proper drainage.
Under normal conditions, drain the intermediate
once each year and refill with approximately 7−1/2
ounces (22 ml) of clean oil. Change the oil more fre-
quently if the pump is operated continuously or in-
stalled in an environment with rapid temperature
change.
Monitor the condition of the bearing lubri-
cant regularly for evidence of rust or mois-
ture condensation. This is especially im-
portant in areas where variable hot and
cold temperatures are common.
For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.
Engine
Consult the literature supplied with the power
source, or contact your local Deutz engine repre-
sentative.