Gorman-Rupp Pumps 16C2-F4L 913960 thru 1013565 User Manual
Page 35

OM−00725−06
10 SERIES
MAINTENANCE & REPAIR
PAGE E − 17
Bearings
(Figure 2)
The intermediate was fully lubricated when
shipped from the factory. Check the oil level regu-
larly through the sight gauge (34)
and maintain it at
the middle of the gauge. When lubrication is re-
quired, add SAE No. 30 non-detergent
oil through
the oil hole cover (20). Do not over-lubricate. Over-
lubrication can cause the bearings to over-heat, re-
sulting in premature bearing failure.
NOTE
The white reflector in the sight gauge must be posi-
tioned horizontally to provide proper drainage.
Under normal conditions, drain the intermediate
once each year and refill with approximately 7 1/2
ounces (0,22 liter) of clean oil. Change the oil more
frequently if the pump is operated continuously or
installed in an environment with rapid temperature
change.
Monitor the condition of the bearing lubri-
cant regularly for evidence of rust or mois-
ture condensation. This is especially im-
portant in areas where variable hot and
cold temperatures are common.
For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.
Engine
Consult the literature supplied with the power
source, or contact your local Deutz engine repre-
sentative.