Troubleshooting - section d – Gorman-Rupp Pumps 16C2-F4L 913960 thru 1013565 User Manual
Page 16
10 SERIES
OM−00725−06
TROUBLESHOOTING
PAGE D − 1
TROUBLESHOOTING − SECTION D
Review all SAFETY information in Section A.
Before attempting to open or service the
pump:
1. Familiarize yourself with this manual.
2. Switch off the engine ignition and re-
move the key to ensure that the pump
will remain inoperative.
3. Allow the pump to cool if overheated.
4. Check the temperature before open-
ing any covers, plates, or plugs.
5. Close the suction and discharge
valves.
6. Vent the pump slowly and cautiously.
7. Drain the pump.
TROUBLE
POSSIBLE CAUSE
PROBABLE REMEDY
PUMP FAILS TO
PRIME
Suction check valve contaminated or
damaged.
Clean or replace check valve.
Air leak in suction line.
Lining of suction hose collapsed.
Correct leak.
Replace suction hose.
Leaking or worn seal or pump gasket.
Check pump vacuum. Replace
leaking or worn seal or gasket.
Suction lift or discharge head too high.
Check piping installation and in-
stall bypass line if needed. See
INSTALLATION.
Strainer clogged.
Check strainer and clean if neces-
sary.
Not enough liquid in casing.
Add liquid to casing. See PRIM-
ING.
Suction check valve or foot valve
clogged or binding.
Clean valve