SAFETY
SAFETY - SECTION A
This information applies to 10 Series
Engine Driven pumps. Refer to the man
ual accompanying the engine before at
tempting to begin operation.
Because pump installations are seldom
identical, this manual cannot possibly
provide detailed instructions and pre
cautions for each specific application.
Therefore, it is the owner/installer's re
sponsibility to ensure that applications
not addressed in this manual are per
formed only after establishing that nei
ther operator safety nor pump integrity
are compromised by the installation.
Before attempting to install, operate, or
service this pump, familiarize yourself
with this manual, and with all other liter
ature shipped with the pump. Unfamil
iarity with all aspects of pump operation
covered in this manual could lead to de
struction of equipment, injury, or death
to personnel.
Before attempting to open or service the
pump:
1. Familiarize yourself with this man
ual.
2. Switch off the engine ignition and
disconnect the positive battery
cable to ensure that the pump will
remain inoperative.
3. Allow the pump to completely cool
if overheated.
4. Check the temperature before
opening any covers, plates, or
plugs.
5. Close the suction and discharge
valves.
6. Vent the pump slowly and cau
tiously.
7. Drain the pump.
This pump is designed to handle dirty
water containing specified entrained
solids. Do not attempt to pump volatile,
corrosive, or flammable materials, or
any liquids which may damage the
pump or endanger personnel as a result
of pump failure.
Use lifting and moving equipment in
good repair and with adequate capacity
to prevent injuries to personnel or dam
age to equipment. Suction and dis
charge hoses and piping must be re
moved from the pump before lifting.
After the pump has been positioned,
make certain that the pump and all pip
ing or hose connections are tight, prop
erly supported and secure before oper
ation.
Do not operate the pump against a
closed discharge valve for long periods
of time. If operated against a closed dis
charge valve, pump components will
deteriorate, and the liquid could come
to a boil, build pressure, and cause the
pump casing to rupture or explode.