Alignment – Gorman-Rupp Pumps 16C20-F4L 1317844 and up User Manual
Page 15
OM-01604
10 SERIES
PAGE B - 8
INSTALLATION
DISCHARGE PIPE
DISCHARGE
CHECK VALVE
PUMP DISCHARGE
SELF‐PRIMING
CENTRIFUGAL
PUMP
SUCTION
LINE
SUPPORT
BRACKET
CLEAN‐OUT
COVER
INSTALL AIR RELEASE VALVE
IN HORIZONTAL POSITION
90
_ LONG
RADIUS
ELBOW
WET WELL
OR SUMP
BLEED LINE 1”
(25,4 MM) DIA. MIN.
(CUSTOMER FUR
NISHED) DO NOT EX
TEND BELOW PUMP
OFF LIQUID LEVEL
Figure 6. Typical Automatic Air Release Valve Installation
The valve inlet line must be installed between the
pump discharge port and the non‐pressurized side
of the discharge check valve. The valve inlet is at
the large end of the valve body, and is provided
with standard 1 inch NPT pipe threads.
The valve outlet is located at the opposite end of
the valve, and is also equipped with standard 1
inch NPT pipe threads. The outlet should be con
nected to a bleed line which slopes back to the wet
well or sump. The bleed line must be the same size
as the inlet piping, or larger. If piping is used for the
bleed line, avoid the use of elbows whenever pos
sible.
NOTE
It is recommended that each Air Release Valve be
fitted with an independent bleeder line directed
back to the wet well. However, if multiple Air Re
lease Valves are installed in a system, the bleeder
lines may be directed to a common manifold pipe.
Contact your Gorman‐Rupp distributor or the Gor
man‐Rupp Company for information about installa
tion of an Automatic Air Release Valve for your spe
cific application.
ALIGNMENT
The alignment of the pump and the engine is criti
cal for trouble‐free mechanical operation. See Sec
tion E, Securing Intermediate And Drive Assem
bly To Engine for detailed information.