Operation - section c – Gorman-Rupp Pumps 16C20-F5L 1338868 and up User Manual
Page 15
10 SERIES
OM−02616
OPERATION
PAGE C − 1
OPERATION − SECTION C
Review all SAFETY information in Section A.
Follow the instructions on all tags, labels and
decals attached to the pump.
Do not operate an internal combustion
engine in an explosive atmosphere.
When operating internal combustion
engines in an enclosed area, make cer-
tain that exhaust fumes are piped to the
outside. These fumes contain carbon
monoxide, a deadly gas that is color-
less, tasteless, and odorless.
This pump is designed to handle dirty
water containing specified entrained
solids. Do not attempt to pump volatile,
corrosive, or flammable materials, or
any liquids which may damage the
pump or endanger personnel as a result
of pump failure.
Never tamper with the governor to gain
more power. The governor establishes
safe operating limits that should not be
exceeded. The maximum continuous
operating speed for this pump is 2200
RPM.
PRIMING
Install the pump and piping as described in IN-
STALLATION. Make sure that the piping connec-
tions are tight, and that the pump is securely
mounted. Check that the pump is properly lubri-
cated (see LUBRICATION in MAINTENANCE
AND REPAIR).
This pump is self-priming, but the pump should
never be operated unless there is liquid in the
pump casing.
Never operate this pump unless there is
liquid in the pump casing. The pump will
not prime when dry. Extended operation of
a dry pump will destroy the seal assembly.
Add liquid to the pump casing when:
1. The pump is being put into service for the
first time.
2. The pump has not been used for a consider-
able length of time.
3. The liquid in the pump casing has evapo-
rated.
Once the pump casing has been filled, the pump
will prime as necessary.
After filling the pump casing, reinstall
and tighten the fill plug. Do not attempt
to operate the pump unless all connect-
ing piping is securely installed. Other-
wise, liquid in the pump forced out un-
der pressure could cause injury to per-
sonnel.
To fill the pump, remove the pump casing fill cover
or fill plug at the top of the casing and add clean
liquid until the pump is filled. Replace the fill cover
or fill plug before operating the pump.
NOTE
This pump is self-priming; however, it is not suited
for unattended reprime applications. In the event of
suction check valve failure and loss of prime, the
pump casing must be refilled through the fill cover
or fill plug.